Set Command Library

TLT,INTVL: Defining the Time Interval to Acquire Tiltmeter Data

Function

This command is used to define the time interval through
which the receiver will regularly ask the tiltmeter to return its
data. The command also specifies the ID of the receiver port
used to communicate with the tiltmeter.

By default, the receiver will query the tiltmeter every second
once the receiver has notified the tiltmeter, through the
$PASHS,OUT,x,TLT,ON command, to start operating.

Command Format

Syntax

$PASHS,TLT,INTVL,c1,d2[*cc]

Parameters

Example

Setting query interval to 10 seconds, tiltmeter on port F:

$PASHS,TLT,INTVL,F,10*1B

Relevant Query

Command

$PASHQ,TLT

See Also

$PASHS,TLT,CMD

$PASHS,TLT,INIT

$PASHS,OUT,x,TLT

Parameter

Description

Range Default

c1

Receiver serial port connected to the tiltmeter.

A, B, F

d2

Query interval, in seconds

1-86400 1

*cc

Optional checksum

*00-*FF

Advertising