Sequences - times (6.0) – ETC Congo Family v6.4.0 User Manual

Page 401

Advertising
background image

399

Sequences - Times (6.0)

You can set times to a sequence step, and all channels and moving device parameters will
follow that time.

You can also set individual times in seconds, or as a percentage of the in- and delay times
for each channel and moving device parameter in a sequence step.

Times are set from, like this: 0.01 – 9.99. seconds to 49.59 minutes (0.1- 4959). It is possible
to use hundreds of seconds as input during the first 10 seconds (v6.0)

When no time is set to a sequence step, the default time (5seconds) will be used. Change
this setting by holding SETUP and pressing A.

The easiest way to set times to ANY step of the sequence in the main playback is to use the
TIME EDITOR. Enter the number of the step, hold MODIFY and press TIME. See

The Time

Editor Popup

.

NOTE
Fade times of a Sequence Step are related to that step, not to the
Preset occupying the Step. This makes it possible to use the same
Preset with different fade times in other Steps or in the Masters.

To edit the times for a step open the Sequence List.

Sequence Times - Set To A or B

Times are set to A or B depending on what situation you are working in. The current setting
is indicated with an arrow next to the times:

It is possible to toggle if times are set to A or B by holding TIME and pressing A or B.