Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 117

Advertising
background image

5–7

Programming Parameters

Publication 1397-5.0 — June, 2001

PARM

NAME

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

Feedback Type

Maximum Current

Max Motor Speed

Max Process Speed

Min Process Speed

Motor Field Amps

Motor Arm Amps

Motor Arm Volts

Anlg Tach V/100

Encoder PPR

Encoder Quad

Nominal AC Freq

Nominal AC Volts

Auto Tune Type

SETUP 2

SETUP 3

SETUP 4

SETUP 5

Anlg Tach Gain

Anlg Tach Zero

Arm Voltage Gain

Arm Voltage Zero

Cur Loop K–Fdbk

Cur Lp Lead Freq

Cur Loop Kp

Cur Loop Rate Lim

METERING 5

IR Compensation

Pos Cur Lim

Neg Cur Lim

Pos Cur Lim Src

Neg Cur Lim Src

PLL Max Error

Spd Lead Lag Freq

Spd Lead Lag Rato

Spd Lead Lag Type

Spd Lp Lag Freq

Spd Lp Lag Type

Spd Lp Lead Freq

Spd Loop Kp

UNITS

Selection

FLA

RPM

RPM

RPM

AMPS

AMPS

VOLTS

Volts per RPM

PPR

Selection

Hz

VAC

(Hidden)

(Hidden)

(Hidden)

(Hidden)

rad/sec

ms

(Hidden)

%FLA

%FLA

%FLA

ENUM

ENUM

uSEC

rad/sec

ratio

selection

rad/sec

selection

rad/sec

MIN

MAX

DEFAULT

FUNCTION

Setup

Setup

Setup

Setup

Setup

Setup

Setup

Setup

Setup

Setup

Setup

Adv Setup

Adv Setup

Setup

Setup

Setup

Setup

Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

Adv Setup

TYPE

Configurable

Tunable

Configurable

Tunable

Tunable

Configurable

Configurable

Configurable

Configurable

Configurable

Configurable

Configurable

Configurable

Configurable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

Configurable

Configurable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

Tunable

(0) Arm Volt

25%

5

1

0

0.11

0.1

160

18.0v

18

1 (On)

48Hz

200V

0

FUTURE

FUTURE

FUTURE

FUTURE

0.750

–200

0.750

–200

1.000

10

0.000

1

FUTURE

0%

0

0

0

0

2

1

2

0 (Lead/Lg)

0.01

0

0.00

0.10

(3)AC Tach

200%

5000

User Defined

User Defined

ISR

3000

675

200.v

2500

0 (Off)

62 HZ

575V

3

USE

USE

USE

USE

1.250

200

1.250

200

1.100

500

4.000

100

USE

50%

150%

150%

9

9

1000

3490

20

2(Lag/Lead)

69.81

1

141.37

128.0

(0) Arm Volt

150%

500

500

250

0.01

8

240

18.0v

18

1 (On)

50 or 60Hz

230VAC

0

1.000

0

1.000

0

1.000

100

0.250

40

0%

150%

150%

0(Register)

0(Register)

1.00

100

2

1(Bypass)

1.00

1

3.00

4.40