Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 145
5–35
Programming Parameters
Publication 1397-5.0 — June, 2001
REFERENCE SET
[Preset Speed 1, 2 and 3] — P.87, P.88 and P.89
These parameters set up to three preset
speed references when the Regulator Type
jumper (J15 on the regulator board) is set for
the speed/voltage control loop or current
reference when J15 is set to current.
Display/Drive Units:
%FLA
Parameter Range:
0 to [Maximum Current] — %FLA
Default Setting:
150 %FLA
Parameter Type:
Tunable
Group:
Reference Set
Display/Drive Units:
RPM
OR
Parameter Range:
[Min Process Speed] to [Max Process Speed] RPM
Default Setting:
250 RPM
Parameter Type:
Tunable
Group:
Reference Set
Factory Default:
250
Minimum Value:
Min Process Speed
Maximum Value:
Max Process Speed
[Ref 1 Source] — P.090
Selects the source of external reference 1
Display/Drive Units:
Numeric/Text
Parameter Range:
0 = Anlg In 1
1 = Speed Pot
2 = MOP Output
3 = Anlg In 3
4 = Anlg In 4
5 = Frequency In
6 = Adapter 1
7 = Adapter 2
8 = Adapter 3
9 = Adapter 4
10 = Adapter 5
11 = Adapter 6
12 = Preset 1
13 = Preset 2
14 = Preset 3
Parameter Type:
R & W
Group:
Reference Set
Factory Default:
0
Minimum Value:
0
Maximum Value:
14