Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 131
5–21
Programming Parameters
Publication 1397-5.0 — June, 2001
METERING
[Speed Pot] — P.029
Analog reference value, scaled to max and
min Process Speed, measured by the drive
after all hardware and software scaling.
Display/Drive Units:
RPM
Group:
Metering
Type:
Factory Default:
0
Minimum Value:
–5000.0
Maximum Value:
5000.0
[Trim Output] — P.030
Shows the value of trim that will be added to
speed reference[Spd Src Output]
Actual Min/Max values will be determined by
Motor Arm Volts (P. 046) or Max Motor Speed
(P.041)
Display/Drive Units:
RPM
Group:
Metering
Type:
Factory Default:
0
Minimum Value:
–5000.0
Maximum Value:
5000.0
[Torque Reference] — P.031
Shows the value (in amps) of the currently
selected reference to the drive (see Fig. A.3).
Display/Drive Units:
AMPS
Group:
Metering
Type:
Factory Default:
O
Minimum Value:
–960.0
Maximum Value:
960.0