Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 182

Advertising
background image

5–72

Programming Parameters

Publication 1397-5.0 — June, 2001

MASKS

[Start Mask] — P.201

This parameter controls which adapters can
issue Run commands.

Display/Drive Units:

Numeric/Text

Parameter Range:

Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6

Parameter Type:

Read & Write

Group:

Masks

Minimum Value:

0000000000000000

Factory Default:

0000000001111111

Maximum Value:

0000000001111111

[Direction Mask] — P.202

This parameter controls which adapters can
issue forward/reverse commands. This mask
contains a bit for each adapter. If a bit is set
to 0 control is locked out, if it is set to 1, the
adapter is permitted to have control.

Display/Drive Units:

Numeric/Text

Parameter Range:

Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6

Group:

Masks

Minimum Value:

0000000000000000

Factory Default:

0000000001111111

Maximum Value:

0000000001111111

[Jog Mask] — P.203

This parameter controls which adapters can
issue jog commands.

Display/Drive Units:

Numeric/Text

Parameter Range:

Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6

Parameter Type:

Read & Write

Group:

Masks

Minimum Value:

0000000000000000

Factory Default:

0000000001111111

Maximum Value:

0000000001111111

Advertising