5–84

Programming Parameters

Publication 1397-5.0 — June, 2001

Process Display

[Process 1 Text 7] — P.255

Sets the “User Units” description for the value
determined by [Process 1 Par] and [Process 1
Scale]. The 8 character description will be
shown on line 1 of the display.

Display/Drive Units:

Numeric/Text

Parameter Range:

Alphanumeric

Parameter Type:

Read & Write

Group:

Process Display

Minimum Value:

32

Factory Default:

32

Maximum Value:

127

[Process 1 Text 8] — P.256

Sets the “User Units” description for the value
determined by [Process 1 Par] and [Process 1
Scale]. The 8 character description will be
shown on line 1 of the display.

Display/Drive Units:

Numeric/Text

Parameter Range:

Alphanumeric

Parameter Type:

Read & Write

Group:

Process Display

Minimum Value:

32

Factory Default:

32

Maximum Value:

127

[Process 2 Par] — P.257

This parameter should be set to the number
of the parameter whose scaled value will be
displayed on Line 2 of the HIM Display Panel.

Display/Drive Units:

Numeric/Text

Parameter Range:

Alphanumeric

Parameter Type:

Read & Write

Group:

Process Display

Minimum Value:

0

Factory Default:

6

Maximum Value:

308

[Process 2 Scale] — P.258

This value sets the scaling multiplier for
[Process 2 Par].

Display/Drive Units:

Numeric/Text

Parameter Range:

–3127.69 – +327.68

Parameter Type:

Read & Write

Group:

Process Display

Minimum Value:

–32768

Factory Default:

100

Maximum Value

32767