Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 127

Advertising
background image

5–17

Programming Parameters

Publication 1397-5.0 — June, 2001

METERING

[Jog Ramp Output] — P.012

An output that represents the jog reference
value immediately after the jog ramp function.

Display/Drive Units:

RPM

Group:

Metering

Type:

Read Only

Factory Default:

0

Minimum Value:

–5000

Maximum Value:

5000

[Monitor 1 Output] — P.013

Shows the present state of the respective
monitor (On, Off).

Display/Drive Units:

Enum Text

Group:

Metering

Factory Default:

0

Minimum Value:

0 (Off)

Maximum Value:

1 (On)

[Monitor 2 Output] — P.014

Shows the present state of the respective
monitor (On, Off).

Display/Drive Units:

Enum Text

Group:

Metering

Factory Default:

0

Minimum Value:

0 (Off)

Maximum Value:

1 (On)

[MOP Output] — P.015

The output of the motor operated
potentiometer (MOP).

Refer to the [MOP Accel Time] input
parameter and block diagram for additional
information.

Display/Drive Units:

RPM

Group:

Metering

Parameter Type:

Read Only

Factory Default:

0

Minimum Value:

–5000

Maximum Value:

5000