Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 187

Advertising
background image

5–77

Programming Parameters

Publication 1397-5.0 — June, 2001

OWNERS

[Flt Reset Owner] — P.219

This parameter displays which parameter is
currently resetting a fault.

Display/Drive Units:

Numeric/Text

Parameter Range:

Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6

Parameter Type:

Read Only

Group:

Owners

Minimum Value:

0000000000000000

Factory Default:

0000000000000000

Maximum Value:

0000000001111111

[MOP Owner] — P.220

This parameter displays which adapters are
currently issuing increases or decreases in
MOP Command Frequency.

Display/Drive Units:

Numeric/Text

Parameter Range:

Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6

Parameter Type:

Read Only

Group:

Owners

Minimum Value:

0000000000000000

Factory Default:

0000000000000000

Maximum Value:

0000000001111111

[Local Owner] — P.221

This parameter displays which adapter has
requested exclusive control of all drive logic
functions. If an adapter is in local lockout, all
other functions (except stop) on all other
adapters are locked out and non–functional.
Local control can only be obtained when the
drive is not running.

Display/Drive Units:

Numeric/Text

Parameter Range:

Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6

Parameter Type:

Read Only

Group:

Owners

Minimum Value:

0000000000000000

Factory Default:

0000000000000000

Maximum Value:

0000000001111111