Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 20

Advertising
background image

2–2

Installation

Publication 1397-5.0 — June, 2001

In order to maintain proper cooling, the Drive must be mounted in a
vertical position. Refer to Figure 2.1 for the recommended minimum
clearance of each Drive.

The Drive design produces up to a 10

°C or 18°F air temperature rise

when the Drive is operated at full capacity. Precautions should be
taken not to exceed the maximum inlet ambient air temperature of
55

°C (131°F). If the Drive is in an enclosed cabinet, air circulation

fans or a closed circuit heat exchanger may be required.

For information on installing, wiring and grounding Line Filters used
in CE compliant applications, refer to Appendix B.

For installation information on AC Line Inductors used in CE
compliant applications, refer to Appendix B.

Cooling Airflow

Line Filters (CE Only)

AC Line Inductors (CE Only)