5–64

Programming Parameters

Publication 1397-5.0 — June, 2001

DIAGNOSTICS

[Armature Delta] — P.172

Shows the actual firing angle (in

µs).

Display/Drive Units:

uSEC

Parameter Type:

Output

Group:

Diagnostics

Factory Default:

0

Minimum Value:

–6480

Maximum Value:

6480

[Cur Compound TP] — P.173

An output testpoint that represents the
current compounding value being used by
the drive.

Display/Drive Units:

RPM

Parameter Type:

N/A

Group:

Diagnostics

Factory Default:

0

Minimum Value:

–4095

Maximum Value:

4095

[Field Delta] — P.174

The firing angle of the output of the field
current regulator to the regulated field supply
gate firing circuit. Output of the field current PI
block.

Display/Drive Units:

DEG

Group:

Diagnostics

Parameter Type:

Read Only

Factory Default:

0

Minimum Value:

–5400

Maximum Value:

5400

[Fld Econ Active] — P.175

Indicates the present state of field economy
mode.

Display/Drive Units:

Numeric/Text

Parameter Range:

0 = Not Active
1 = Active

Parameter Type:

Read Only

Group:

Diagnostics

Factory Default:

0

Minimum Value:

0

Maximum Value:

1