Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 149

Advertising
background image

5–39

Programming Parameters

Publication 1397-5.0 — June, 2001

FEATURE SELECT

[Inertia Comp Src] — P.102

Sets the source of the inertia compensation
signal.
Internal uses [Normal Inertia] and [Maximum
Current] params to determine amount of
inertia compensation.

Display/Drive Units:

Numeric/Text

Parameter Range:

0 = NONE
1 = INTERNAL
2 = ANLG IN 3
3 = ANLG IN 4
4 = FREQUENCY IN
5 = ADAPTER 1
6 = ADAPTER 2
7 = ADAPTER 3
8 = ADAPTER 4
9 = ADAPTER 5
10 = ADAPTER 6

Group:

Feature Select

Factory Default:

0

Minimum Value:

0

Maximum Value:

10

[Monitor 1 Delay] — P.103

The delay time in seconds for the level
detector 1 circuit. Sets the amount of time
between when the level detector timer is
triggered and when the output is set on. If the
input source signal goes below the detector’s
threshold value, the timer is immediately
reset. Refer to the Level Detectors block
diagram (Fig. A.12) for additional Information.

Display/Drive Units:

SECS

Default Setting:

10.0 seconds

Parameter Type:

Tunable

Group:

Feature Select

Factory Default:

1.0

Minimum Value:

0

Maximum Value:

300.0