5–20

Programming Parameters

Publication 1397-5.0 — June, 2001

METERING

[Spd Loop Ref] — P.025

An output that represents the reference value
to be used by the speed loop regulator in the
drive.

Display/Drive Units:

RPM

Group:

Metering

Type:

Factory Default:

0

Minimum Value:

–5000.0

Maximum Value:

5000.0

[Spd Src Output] — P.026

The user selected speed reference source
value. It is an input to the speed reference
ramp section.

Display/Drive Units:

RPM

Group:

Metering

Type:

Factory Default:

0

Minimum Value:

–5000.0

Maximum Value:

5000.0

[Spd Ramp In TP] — P.027

An output that represents the test point value
immediately before the speed loop ramp
function.

Display/Drive Units:

RPM

Group:

Metering

Type:

Factory Default:

0

Minimum Value:

–5000.0

Maximum Value:

5000.0

[Spd Ramp Output] — P.028

An output that represents the test point value
immediately after the speed loop ramp
function.

Display/Drive Units:

RPM

Group:

Metering

Type:

Factory Default:

0

Minimum Value:

–5000.0

Maximum Value:

5000.0