Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 158
5–48
Programming Parameters
Publication 1397-5.0 — June, 2001
INPUT CONFIG
[Anlg In 2 Zero] — P.131
Removes any hardware introduced offset
from the analog reference signal. Typically, it
will be 0.
Display/Drive Units:
Numeric
Parameter Range:
– 200 to + 200
Parameter Type:
Tunable
Group:
Input Config
Factory Default:
0
Minimum Value:
–200
Maximum Value:
200
[Anlg In 3 Gain] — P.132
Only used if the I/O Expansion kit is installed.
Scales analog input 3 (Terminals 50 & 51 on
the I/O Exp). Typically 1.000
Display/Drive Units:
Numeric
Group:
Input Config
Parameter Type
Tunable
Factory Default:
1.000
Minimum Value:
0.750
Maximum Value:
2.250
[Anlg In 3 Type] — P.133
Only used if the I/O Expansion kit is installed.
Selects the type of signal that the drive will
expect to be connected to analog input 3
(terminals 50 and 51 on the I/O Expansion
board).The value of this parameter must
match the setting of jumpers J11 and J12 on
the I/O Expansion board.
Refer to the I/O Expansion Inputs (Fig. A.2)
block diagram for further information.
Display/Drive Units:
Numeric
Parameter Range:
0 = 0-10V
1 =
±10V
2 = 4 -20mA
3 = 10-50mA
Default Setting:
±10V
Group:
Input Config
Factory Default:
1
Minimum Value:
0
Maximum Value:
3