5–82

Programming Parameters

Publication 1397-5.0 — June, 2001

Process Display

[Process 1 Par] — P.247

This parameter should be set to the number
of the parameter whose scaled value will be
displayed on Line 1 of the HIM Display Panel.

Display/Drive Units:

Numeric/Text

Parameter Type:

Read & Write

Group:

Process Display

Minimum Value:

0

Factory Default:

5

Maximum Value:

308

[Process 1 Scale] — P.248

This value sets the scaling multiplier for
[Process 1 Par].

Display/Drive Units:

Numeric/Text

Parameter Type:

Read & Write

Group:

Process Display

Minimum Value:

–32768

Factory Default:

1.00

Maximum Value:

32767

[Process 1 Text 1] — P.249

Sets the “User Units” description for the value
determined by [Process 1 Par] and [Process
1 Scale]. The 8 character description will be
shown on line 1 of the display.

Display/Drive Units:

Numeric/Text

Parameter Range:

Alphanumeric

Parameter Type:

Read & Write

Group:

Process Display

Minimum Value:

32

Factory Default:

86

Maximum Value:

127

[Process 1 Text 2] — P.250

Sets the “User Units” description for the value
determined by [Process 1 Par] and [Process 1
Scale]. The 8 character description will be
shown on line 1 of the display.

Display/Drive Units:

Numeric/Text

Parameter Range:

Alphanumeric

Parameter Type:

Read & Write

Group:

Process Display

Minimum Value:

32

Factory Default:

111

Maximum Value:

127