Appendix

A

Publication 1397-5.0 — June, 2001

Firmware Block Diagrams

Figure A.1
Standard Inputs

Max Motor Speed
(P. 041)

LIMIT

HI

LO

Anlg In 1
Type
(P. 128)

MAX MOTOR SPEED

DRAW PERCENT OUT

SOFTWARE SCALING

Analog Input 1
(+) CTB–19
(–) CTB – 20

To Any Switch
Selection
Labeled
“ANLG IN 1”

ANALOG
INPUTS

A/D

Anlg
In1 Type
(P. 128)

Anlg
In1 Zero
(P. 129)

Anlg
In1 Gain
(P. 127)

+/– 10V

0 – 10V

4 – 20 mA

10 – 50 mA

Anlg In 2
Gain
(P. 130)

SOFTWARE
SCALING

A/D

Analog
In2 Zero
(P. 131)

Max
Process
Speed
(P. 042)

Max Process
Speed
P.042)

MAX/MIN
SPD SCALING

HI

LO

0

(Speed Pot)
[P029]

Anlg In 2
[P002]

To Speed/Trim
Reference Block
Diagram labeled
“SPEED POT”

To Any Switch
Selection
Labeled
“ANLG IN 2”

Min Process
Speed
(P. 043)

0

1 J19 must be set to POT (2–3) to
use the internal 10V power supply

* = Default Selection

Max Motor
Speed
(P. 041)

Analog Input 2
(+) CTB–17
(–) CTB – 28
1 > (10V) CTB–16

– Max Motor Speed