Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 71

Advertising
background image

3–13

Programming Terminal

Publication 1397-5.0 — June, 2001

or

(continued)

Control Status Mode

Fault Queue/Clear Faults

or

or

or

2. This menu provides a means to view the

fault queue and clear it when desired.

F. From the Control Status menu, press the

Increment (or Decrement) key until
“Fault Queue” is displayed.

G. Press Enter.

H. Press the Increment (or Decrement) key

until “View Faults” is displayed.

I. Press Enter. The fault queue will be

displayed. “Trip” displayed with a fault
will indicate the fault that tripped the
drive.

J. Use the Increment (or Decrement) key

to scroll through the list.

K. To clear the fault queue, press ESCape.

Then use the Increment/Decrement keys
to select “Clear Queue.” Press Enter.
Please note that “Clear Queue” will also
clear active fault conditions.

Control Status
Fault Queue

Fault Queue
View Faults

CAN Comm Lost
F 11 Trip 1

Motor Over Temp
F 07 2

Fault Queue
Clear Queue

or

Warning Queue/Clear Warning

or

3. This menu provides a means to view the

Warning queue and clear it when desired.

L. From the Control Status menu, press the

Increment (or Decrement) key until
“Warning Queue” is displayed.

M. Press Enter.

N. Press the Increment (or Decrement) key

until “View Warnings” is displayed.

O. Press Enter. The Warning queue will be

displayed. “Trip” displayed with a fault
will indicate the fault that tripped the
drive.

P. Use the Increment (or Decrement) key

to scroll through the list.

Q. To clear the Warning queue, press

ESCape. Then use the Inc/Dec keys to
select “Clear Queue.” Press Enter.
Please note that “Clear Queue” will also
clear active warning conditions.

Control Status
Warning Queue

Warning Queue
View Warnings

Brush Wear Low
W 01 1

Sustained Speed
W 32 2

Warning Queue
Clear Queue