Advertising
background image

3.2. Remote control commands

751 GPD Titrino

120

*Parameter Tree part "Parameters for SET"

Ã

.

SET1

Control parameters for EP1

³ Ã

.EP

Endpoint 1

depends on meas.quant. 3.2.2.29.

³ Ã

.UnitEp

Unit of endpoint

read only

ditto

³ Ã

.Dyn

Dynamics

depends on meas.quant. 3.2.2.30.

³ Ã

.UnitDyn

Unit of dynamics

read only

ditto

³ Ã

.MaxRate

Maximum dosing rate

0.01...10...150, max.

ditto

³ Ã

.MinRate

Minimum dosing rate

0.01...25.0...9999

ditto

³ Ã

.Stop

Titration stop

³ ³ Ã

.Type

Type of stop criterion

drift, time

3.2.2.31.

³ ³ Ã

.Drift

Stop drift

1...20...999

ditto

³ ³ Ã

.Time

Switch-off delay time

0...10...999, inf

ditto

³ ³ Ã

.StopT

Stop time

0...999 999, OFF

ditto

Ã

.

SET2

Control parameters for EP2, as for EP1

Ã

.

TitrPara

Titration parameters

³ Ã

.Direction

Titration direction

+, -, auto

3.2.2.32.

³ Ã

.XPause

Waiting time before start volume

0...999 999

3.2.2.33.

³ Ã

.Start V

Start volume

³ ³ Ã

.Type

Type of start volume

abs., rel., OFF

3.2.2.15.

³ ³ Ã

.V

Volume for absolute start volume

0...999.99

ditto

³ ³ Ã

.Factor

Factor for relative start volume

0...

±

999 999

ditto

³ ³ Ã

.Rate

Dispensing rate for start volume

0.01...150.0, max.

ditto

³ Ã

.Pause

Waiting time after start volume

0...999 999

3.2.2.16.

³ Ã

.ExtrT

Extraction time

0...999 999

3.2.2.34.

³ Ã

.DosUnit

Selection of the dosing unit

internal D0, external D1,

³ ³

external D2

3.2.2.17.

³ Ã

.MeasInput

Measuring input

1, 2, diff.

3.2.2.18.

³ Ã

.Ipol

Polarization current

0...1...

±

127

ditto

³ Ã

.Upol

Polarization voltage

0...400...

±

1270

ditto

³ Ã

.PolElectrTest

Test for polarized electrodes

ON, OFF

ditto

³ Ã

.Temp Titration temperature

-170.0...25.0...500.0

3.2.2.19.

³ Ã

.TDelta

Time interv. for meas.acquisition

1...2...999 999

3.2.2.35.

³

Ã

.

StopCond

Stop conditions

³ Ã

.VStopStop volume

³ ³ Ã

.Type

Type of stop volume

abs., rel., OFF

3.2.2.20.

³ ³ Ã

.V

Volume for absolute stop volume

0...99.99...9999.99

ditto

³ ³ Ã

.Factor

Factor for relative stop volume

0...

±

999 999

ditto

³ Ã

.FillRate

Filling rate

0.01...150.0, max.

3.2.2.23.

³

Ã

.

StatisticsStatistics

³ Ã

.Status

Status of statistics calculation

ON, OFF

3.2.2.24.

³ Ã

.MeanN

No. of individual determinations

2...20

ditto

³ Ã

.ResTab

Result table

³ ³ Ã

.Select

original,delete n,delete all

ditto

³ ³ Ã

.DelN

Deletion of individual results

1...20

ditto

³

Ã

.

Presel

Preselections

³ Ã

.Cond

Conditioning

ON, OFF

3.2.2.36.

³ Ã

.DriftDisp

Display of drift during cond.

ON, OFF

ditto

³ Ã

.DCor

Drift correction

³ ³ Ã

.Type

Type of drift acquisition

auto, man., OFF

ditto

³ ³ Ã

.Value

Drift value for manual drift corr.

0.0...99.9

ditto

³ Ã

.IReq

Request of Id's after start

id1, id1&2, all, OFF

3.2.2.26.

³ Ã

.SReq

Request of smpl size after start

value, unit, all, OFF

ditto

³ Ã

.LimSmplSize

Limits for sample size

3.2.2.27

³ ³ Ã

.Status

Status of limit control

ON, OFF

ditto

³ ³ Ã

.LoLim

Lower limit

0.0...999 999

ditto

³ ³ Ã

.UpLim

Upper limit

0.0...999 999

ditto

³ Ã

.ActPulse

Output of a pulse

first, all, cond., OFF

3.2.2.28.