3.2. Remote control commands

751 GPD Titrino

122

*Parameter Tree part "Parameters for STAT"

Ã

.

CtrlPara

Control parameters

³ Ã

.EP

Measuring point

depends on meas.quant. 3.2.2.36.

³ Ã

.UnitEp

Unit of endpoint

read only

ditto

³ Ã

.Dyn

Dynamics

depends on meas.quant. 3.2.2.37.

³ Ã

.UnitDyn

Unit of dynamics

read only

ditto

³ Ã

.MaxRate

Maximum dosing rate

0.01...10...150, max.

ditto

³ Ã

.MinRate

Minimum dosing rate

0.01...25.0...9999

3.2.2.40.

³ ³

Ã

.

TitrPara

Titration parameters

³ Ã

.StartVStart volume

³ ³ Ã

.Type

Type of start volume

abs., rel., OFF

3.2.2.15.

³ ³ Ã

.V

Volume for absolute start volume

0...999.99

ditto

³ ³ Ã

.Factor

Factor for relative start volume

0...

±

999 999

ditto

³ ³ Ã

.Rate

Dispensing rate for start volume

0.01...150.0, max.

ditto

³ Ã

.Pause

Waiting time after start volume

0...999 999

3.2.2.16.

³ Ã

.Tstart Start time

0...999 999

3.2.2.41.

³ Ã

.StartMeas

Start measuring value

depends on meas.quant.

ditto

³ Ã

.RateStart

Start rate

0.01...150, OFF

ditto

³ Ã

.TDelta

Time interv.for meas.acquisition

1...2...999 999

3.2.2.34.

³ Ã

.Direction

Titration direction

+, -, auto

3.2.2.31.

³ Ã

.DosUnit

Selection of the dosing unit

internal D0, external D1,

³ ³

external D2

3.2.2.17.

³ Ã

.MeasInput

Measuring input

1, 2, diff.

3.2.2.18.

³ Ã

.Ipol

Polarization current

0...1...

±

127

ditto

³ Ã

.Upol

Polarization voltage

0...400...

±

1270

ditto

³ Ã

.PolElectrTest

Test for polarized electrodes

ON, OFF

ditto

³ Ã

.Temp Titration temperature

-170.0...25.0...500.0

3.2.2.19.

³ ³

Ã

.

StopCond

Stop conditions

³ Ã

.TStopStop time

³ ³ Ã

.Type

Type of stop time

abs.,rel.,delta,delay,OFF 3.2.2.42.

³ ³ Ã

.Time

Time for absolute stop time

0...999 999

ditto

³ ³ Ã

.Factor

Factor for relative stop time

0...

±

999 999

ditto

³ ³ Ã

.Delta

Time after EP is once reached

0...999 999

ditto

³ ³ Ã

.Delay

Time after last dosing step

0...999 999

ditto

³ Ã

.VStopStop volume

³ ³ Ã

.Type

Type of stop volume

abs., rel., OFF

3.2.2.20.

³ ³ Ã

.V

Volume for absolute stop volume

0...99.99...9999.99

ditto

³ ³ Ã

.Factor

Factor for relative stop volume

0...

±

999 999

ditto

³ Ã

.RateStop

Stop rate

0.01...150.0, OFF

3.2.2.43.

³ Ã

.FillRate

Filling rate

0.01...150.0, max.

3.2.2.23.

³ ³

Ã

.

StatisticsStatistics

³ Ã

.Status

Status of statistics calculation

ON, OFF

3.2.2.24.

³ Ã

.MeanN

No. of individual determinations

2...20

ditto

³ Ã

.ResTab

Result table

³ ³ Ã

.Select

original,delete n,delete all

ditto

³ ³ Ã

.DelN

Deletion of individual results

1...20

ditto

³ ³