Metrohm 751 GPD Titrino User Manual

Page 175

Advertising
background image

3.2. Remote control commands

751 GPD Titrino

172

$Q sends the last entry into the measuring point list (.MeasPt) or the last entry
into the list of EP's with DET, MET, SET, KFT.
.MeasPt.X"165" Volume (DET, MET), time (STAT, DOS, DOC, SET, KFT,

MEAS), resp. of the MPList in s

.MeasPt.Y"3.654" Measured value (DET, MET), volume (STAT, DOS, DOC, SET,

KFT), resp. of the MPList in mL

.MeasPt.Z1"6.34" Measured value (STAT, DOS, DOC, SET, KFT, MEAS) of the

MPList, format depends on the measured quantity

.MeasPt.Z2"25.8" Temperature of the MPList in °C
.EP.X"1.234" Volume coordinate of the EP
.EP.Y"5.34" Measured value coordinate of the EP

3.2.2.

3.2.2.146.

146. IInfo.A

.ActualInfo.Ov

.Oven.H

.HeatTime

read only

IInfo.A

.ActualInfo.Ov

.Oven.S

.SampleTemp

read only

IInfo.A

.ActualInfo.Ov

.Oven.L

.LowTemp

read only

IInfo.A

.ActualInfo.Ov

.Oven.H

.HighTemp

read only

IInfo.A

.ActualInfo.Ov

.Oven.G

.GasFlow

read only

IInfo.A

.ActualInfo.Ov

.Oven.U

.UnitFlow

read only

$Q sends the current values from a connected KF Oven. If no Oven is con-
nected, the values are empty.
.HeatTime: Heating time of sample in s.
.SampleTemp: Nominal sample temperature in °C.
.LowTemp: Lowest temperature during the sample heating time in °C.
.HighTemp: Highest temperature during the sample heating time in °C.
.GasFlow:

Average gas flow during sample heating time.

.UnitFlow:

Unit of gas flow.

3.2.2.

3.2.2.147.

147. IInfo.A

.ActualInfo.D

.Display.L

.L1

up to 32 ASCII characters

IInfo.A

.ActualInfo.D

.Display.L8

.L8

up to 32 ASCII characters

IInfo.A

.ActualInfo.D

.Display.D

.DelAll

$G

Lines of the display. The display can be written to from the computer. Proceed
as follows:
1. Lock the display, see 3.2.2.163.
2. Delete the whole display (.DelAll).
3. For writing onto the display, the standard character set will be used.
4. Unlock the display, see 3.2.2.163
5. Delete the whole display (.DelAll).
6. Send a value to nod &Config.Aux.ResDisplay (see 3.2.2.105) to refresh the

display.

$Q sends the contents of the corresponding display line.

3.2.2.

3.2.2.148.

148. IInfo.A

.ActualInfo.C

.Comport.N

.Number

read only

$Q sends the comport number of the Titrino where the PC is connected.

3.2.2.

3.2.2.149.

149. IInfo.As

.Assembly.C

.CycleTime

read only

IInfo.As

.Assembly.E

.ExV

read only

Inquiries regarding basic variables of the assembly: Cycle time in s, volume of
the active Exchange Unit in mL.