Metrohm 751 GPD Titrino User Manual

Page 131

Advertising
background image

3.2. Remote control commands

751 GPD Titrino

128

*Parameter Tree part "Parameters for MEAS"

Ã

.

Measuring

Measuring parameters

³ Ã

.SignalDrift

Drift for meas.value acquisition

depends on meas.quant. 3.2.2.63.

³ Ã

.UnitSigDrift

Unit of measured value drift

read only

ditto

³ Ã

.EquTime

Equilibrium time

0...9999, OFF

ditto

³ Ã

.MeasInput

Measuring input

1, 2, diff.

3.2.2.64.

³ Ã

.Ipol

Polarization current

0...1...

±

127

ditto

³ Ã

.Upol

Polarization voltage

0...400...

±

1270

ditto

³ Ã

.PolElectrTest

Test for polarized electrodes

ON, OFF

ditto

³ Ã

.Temp Titration temperature

-170.0...25.0...500.0

3.2.2.65.

³ Ã

.TDelta

Time interv.for meas.acquisition

1...2...999 999

3.2.2.66.

³ ³

Ã

.

Statistics Statistics

³ Ã

.Status

Status of statistics calculation

ON, OFF

3.2.2.24.

³ Ã

.MeanN

No. of individual determinations

2...20

ditto

³ Ã

.ResTab

Result table

³ ³ Ã

.Select

original,delete n,delete all

ditto

³ ³ Ã

.DelN

Deletion of individual results

1...20

ditto

³ ³

Ã

.

Presel

Preselections

³ Ã

.IReq

Request of Id's after start

id1, id1&2, all, OFF

3.2.2.26.

³ Ã

.SReq

Request of sample size after start

value, unit, all, OFF

ditto

³ Ã

.LimSmplSize

Limits for sample size

3.2.2.27

³ ³ Ã

.Status

Status of limit control

ON, OFF

ditto

³ ³ Ã

.LoLim

Lower limit

0.0...999 999

ditto

³ ³ Ã

.UpLim

Upper limit

0.0...999 999

ditto

³ Ã

.ActPulse

Output of a pulse

ON, OFF

3.2.2.28.

*Parameter Tree part "Parameters for CAL"

Ã

.

Calibration

Calibration parameters

³ Ã

.MeasInput

Measuring input

1, 2, diff.

3.2.2.67.

³ Ã

.CalTemp

Calibration temperature

-20.0...25.0...120.0

3.2.2.68.

³ Ã

.Buffer

³ ³ Г

.1

³ ³ ³ Г

.Value

pH value of buffer 1

0...7.00...

±

20.00

3.2.2.69.

³ ³ Г

.2

³ ³ ³ Г

.Value

pH value of buffer 2

0...4.00...

±

20.00, OFF

ditto

³ ³ Ã

:

up to 9 buffers

³ Ã

.SignalDrift

Drift for meas.value acquisition

depends on meas.quant. 3.2.2.70.

³ Ã

.EquTime

Equilibrium time

0...26...9999, OFF

ditto

³ Ã

.ElectrodeId

Electrode identification

8 ASCII char.

3.2.2.71.

³ Ã

.SmplChanger

Calibration on a Titrino

ON, OFF

3.2.2.72.

³ Ã

.ActPulse

Output of a pulse

first, all, OFF

3.2.2.73.

³ ³

Ã

.

Statistics Statistics

³ Ã

.Status

Status of statistics calculation

ON, OFF

3.2.2.24.

³ Ã

.MeanN

No.of individual determinations

2...20

ditto

³ Ã

.ResTab

Result table

³ ³ Ã

.Select

original,delete n,delete all

ditto

³ ³ Ã

.DelN

Deletion of individual results

1...20

ditto