Metrohm 751 GPD Titrino User Manual

Page 146

Advertising
background image

3.2 Remote control commands

751 GPD Titrino

143

3.2.2 Description of the remote control commands

3.2.2.

3.2.2.1.

1.

M

Mode

$G, $S, $H, $C

Start and stop ($G, $S) or hold of the current method (3.2.2.3) with $H and
continue with $C.
$G also serves to continue after inquiries of identifications and sample size af-
ter the start (see 3.2.2.26) as well as after inquiries of calibration temperature
and pH values of buffers (see 3.2.2.68 and 3.2.2.69).

3.2.2.

3.2.2.2.

2.

M

Mode.Q

.QuickMeas

$G, $S

Start and stop of a measurement in the basic mode with the parameters
(measured quantity, measuring input) of the current method. Corresponds to
the <meas/hold> key. In TIP and DOS, the measured quantity is selected with
&Mode.Parameter, see 3.2.2.76 and 3.2.2.56.
With an ongoing measurement, the current mode can be started. This stops the
measurement automatically.

3.2.2.

3.2.2.3.

3.

M

Mode.S

.Select

DET

DET, MET, SET, KFT, STAT, DOS,

DOC, MEAS, CAL, TIP

M

Mode.D

.DETQuantity

pH

pH, U, Ipol, Upol

M

Mode.M

.METQuantity

pH

pH, U, Ipol, Upol

M

Mode.SET

.SETQuantity

pH

pH, U, Ipol, Upol

M

Mode.MEA

.MEASQuantity

pH

pH, U, Ipol, Upol, T

M

Mode.K

.KFTQuantity

Ipol

Ipol, Upol

M

Mode.ST

.STATQuantity

pH

pH, U, Ipol, Upol

M

Mode.DO

.DOCQuantity

pH

pH, U, Ipol, Upol

Selection of the standard mode. Mode and the measured quantity belong to the
complete selection.
If a method is selected from the method memory, the nodes &Mode.Select and
&Mode.XXXQuantity are overwritten with mode and measured quantity of the
corresponding user method.

3.2.2.

3.2.2.4.

4.

M

Mode.N

.Name

read only

Name of the current method in the working memory. $Q sends 8 ASCII char-
acters. Standard methods carry the name ********. The node can be set read
+ write, see 3.2.2.134.

3.2.2.

3.2.2.5.

5.

M

Mode.Def.F

.Def.Formulas.1.F

.1.Formula

EPX, CXX, RSX, +, -, *, /, (, )

M

Mode.Def.F

.Def.Formulas.1.T

.1.TextRS

up to 8 ASCII characters

M

Mode.Def.F

.Def.Formulas.1.D

.1.Decimal

0...22...5

M

Mode.Def.F

.Def.Formulas.1.U

.1.Unit

up to 6 ASCII characters

M

Mode.D

.Def.F

.Formulas.1.L

.1.Limits

ON, OFF

OFF

M

Mode.D

.Def.F

.Formulas.1.Lo

.1.LoLim

00...

±

999 999

M

Mode.D

.Def.F

.Formulas.1.Up

.1.UpLim

00...

±

999 999

M

Mode.D

.Def.F

.Formulas.1.O

.1.Output

active, pulse, OFF

OFF

M

Mode.D

.Def.F

.Formulas.2.F

.2.Formula

etc. up to .9

.9

Advertising