3.2 Remote control commands

751 GPD Titrino

145

Assignment of the statistics calculations. Valid assignments are a requirement
for statistics calculations. In addition, the statistics calculation must be
switched on, see 3.2.2.24. Rules for statistics calculations see page 77.

3.2.2.

3.2.2.10.

10. M

Mode.Def.T

.Def.TempVar.C70

.C70

RSX, EPX, CXX

etc. up to .C79

.C79

Assignment of temporary variables in a submethod for calculations in TIP.

3.2.2.

3.2.2.11.

11. M

Mode.C

.CFmla

M

Mode.C

.CFmla.1.V

.1.Value

00...

±

999 999

M

Mode.C

.CFmla.2.V

.2.Value

etc., up to .19

.19

Calculation constants specific to a method. Stored in the method memory of
the Titrino. Operands specific to the sample (3.2.2.117 and 3.2.2.135) and val-
ues of common variables (3.2.2.109) on the other hand are not stored with the
methods.

3.2.2.

3.2.2.12.

12. M

Mode.P

.Parameter.T

.TitrPara.M

.MptDensity

0...44...9

M

Mode.P

.Parameter.T

.TitrPara.Mi

.MinIncr

0...10.0

10.0...999.9

M

Mode.P

.Parameter.T

.TitrPara.V

.VStep

0...0.10

0.10...9.999

.MptDensity: Parameter for DET: Measuring point density.
.MinIncr: Parameter for DET: Minimum increment in uL. If the minimum in-

crement is set to 0, measured values are stored vs. time.

.VStep:

Parameter for MET: Volume increment in mL. With "0", there is no
dispensing and measured values vs. time are entered in the meas-
uring point list.

3.2.2.

3.2.2.13.

13. M

Mode

.

PParameter.T

.TitrPara.D

.DosRate

0.01...150, max.

max.

Parameters for DET and MET: Dispensing rate for the volume increments in
mL/min. Max. means maximum possible dispensing rate with the Exchange
Unit in current use.

3.2.2.

3.2.2.14.

14. M

Mode.P

.Parameter.T

.TitrPara.S

.SignalDrift pH,U,Ipol:0.5...50

50...999, OFF

Upol: 0.05...50

50...99.9, OFF

M

Mode.P

.Parameter.T

.TitrPara.U

.UnitSigDrift

read only

M

Mode.P

.Parameter.T

.TitrPara.E

.EquTime

0...26

26...9999, OFF

Parameters for DET and MET: Criteria for the measured value acquisition.
Measured value drift in mV/min (with pH, U, Ipol) or uA/min (with Upol), equili-
bration time in s. OFF means that the corresponding criterion is switched off. If
both criteria are OFF, the measured values are acquired immediately after dis-
pensing.
If the equilibration time has never been edited, it is automatically calculated by
the instrument to match the drift, see page 20. After it has been edited once, it
remains in force with the set value.

3.2.2.

3.2.2.15.

15. M

Mode.P

.Parameter.T

.TitrPara.St

.StartV.T

.Type

abs., rel., OFF

OFF