Configuration guidelines – H3C Technologies H3C S12500 Series Switches User Manual

Page 187

Advertising
background image

175

Step Command Remarks

3.

Diagnose the card
problem.

In standalone mode:

test diag-offline slot slot-number

In IRF mode:

test diag-offline chassis

chassis-number slot slot-number

Use either command.
The diagnosis information will be
displayed and saved in logs under

the root directory of the flash. Each

log is named in the format of
diag_slot_time, where slot

indicates where the card is located

and time indicates when the
diagnosis operation is performed.
This command can be executed for
only isolated cards. Other

commands cannot take effect for

such a card.

Configuring in-service hardware failure diagnosis

and failure protection

CAUTION:

Before configuring the hardware-failure-protection auto-down command on a port, make sure that a
backup link exists to avoid service interruption in case the port is shut down.

A hardware failure might cause traffic forwarding failures and service interruption. To improve the

automatic failure detection and handling capabilities of the switch, you can configure in-service
hardware failure diagnosis and failure protection.
The in-service hardware failure diagnosis and failure protection feature covers:

In-service hardware failure detection for chips, cards, and the forwarding service, and automatic fix
actions taken for the detected failures.

Failure protection for ports. When a hardware failure is detected on a port, the switch automatically
shuts down the port.

Failure protection for aggregation groups. When a hardware failure is detected on a member port
of an aggregation group, if the member port is not configured with the hardware-failure-protection
auto-down command but it is not the final port in up state in the aggregation group, the port is shut

down automatically; if the member port is not configured with the command and it is the final port

in up state in the aggregation group, the port will not be shut down; if the member port is

configured with the command, the port is shut down automatically no matter whether it is the final
port in up state in the aggregation group.

Configuration guidelines

Because hardware failure protection is enabled on member ports of an aggregation group, use the

undo hardware-failure-protection auto-down command to disable this feature for the member

ports of all aggregation groups before you enable hardware failure protection for the aggregation
groups.

If a port is automatically shut down due to hardware failure protection, its status displayed with the
display interface command is Protect DOWN. To bring up the port, use the undo shutdown

command on the port.