Heat pump and backup heat operation, Heat pump with outdoor temperature lockouts, Geothermal radiant heat – Honeywell PRESTIGE THX9321 User Manual

Page 100: Heat pump with outdoor temperature

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

68-0311—02

100

HEAT PUMP AND BACKUP HEAT OPERATION

Heat pump with outdoor temperature lockouts

Outdoor temperature lockouts are optional. See Installer Setup options (ISU 3120).

Geothermal Radiant Heat

The thermostat can be setup to control Geothermal Radiant

Heat, Geothermal Forced Air Heat and Backup Heat, all from

one thermostat. The thermostat stages the equipment starting

with the Geothermal Radiant Heat followed by Geothermal

Forced Air Heat and then Backup Heat as needed to maintain

the desired temperature. The thermostat allows you to set

differential temperature settings between each stage if you

want the equipment to stage a certain way (see ISU 3030 to

ISU 3090, page 31). For additional wiring diagrams, see

page 141.

NOTE: To turn off Radiant Heat during the shoulder sea-

sons, install an outdoor reset control and connect

to the Radiant Heat or switch the thermostat to

Emergency Heat mode.

Electric Backup Heat (Backup Heat Allowed

to Run with Heat Pump)

HEAT MODE

The thermostat turns on Backup Heat only when the indoor

temperature drops to the selected Backup Heat Differential

setting or the Backup Heat Upstage Timer expires (whichever

occurs first). Geothermal Radiant Heat and Geothermal Forced

Air Heat stay on when the Backup Heat turns on.

EMERGENCY HEAT MODE

The thermostat turns on the Backup Heat to maintain the

desired temperature setting. Geothermal Radiant Heat and

Geothermal Forced Air Heat are not used.

Table 8. Heat Pump and Backup Heat Operation.

Backup Heat Type

Backup Heat Operation

Backup Heat Fan Operation

Electric forced air

Allowed to run with heat pump

Thermostat controls fan

Gas or oil forced air

NOT allowed to run with heat pump

Equipment controls fan

Hot water radiant heat

Allowed to run with heat pump

[n/a]

Hot water fan coil

Selectable in installer setup

Thermostat controls fan

Other

Selectable in installer setup

Selectable in installer setup

Heat pump only

Heat pump with backup heat as needed *

Backup heat only

Heat pump only

Heat pump or backup heat operates *

Backup heat only

Outdoor temperature

Outdoor temperature

Backup heat lockout

Backup heat lockout

Compressor lockout

Compressor lockout

*

No backup heat unless indoor temperature drops to selected Backup Heat Differential setting, or Backup Heat
Upstage Timer expires. Heat pump stays ON when backup heat turns on.

*

No backup heat unless indoor temperature drops to selected Backup Heat Differential setting, or Backup
Heat Upstage Timer expires. Heat pump turns OFF when backup heat turns on.

Backup heat allowed to run with heat pump

(see table below)

Backup heat NOT allowed to run with heat pump

(see table below)