BACKUP CONTROL

This section explains when backup control is used. For

example, if batteries in the wireless indoor sensors are

depleted.

If the Thermostat is Part of the Temperature

Average

1. The thermostat controls the system using the remaining

sensors that are part of the temperature average.

2. If there are no remote indoor sensors remaining, the

thermostat controls the system using its internal sensor.

3. If the internal thermostat sensor is not available and a

Return Air Sensor is connected, the Backup Control in

the EIM is used. The backup control maintains 55 °F in

heat, 85 °F in cool and operates the fan continuously to

sense and control temperature.

If the Thermostat is NOT Part of the

Temperature Average

1. The thermostat controls the system using the remaining

sensors that are part of the temperature average.

2. If there are no remote indoor sensors remaining and a

Return Air Sensor is connected, the Backup Control in

the EIM is used. The backup control maintains 55 °F in

heat, 85 °F in cool and operates the fan continuously to

sense and control temperature.

REPLACING A THERMOSTAT

When you replace a thermostat, you must reset the RedLINK

accessories before connecting them to the new thermostat.

Follow the instructions below:

At the Equipment Interface Module (EIM)

1. Press and hold the CONNECT button on the EIM until

the CONNECTED LED glows amber (hold for about 10

seconds).

2. Follow the prompts on the screen to connect the new

thermostat to the EIM. See page 10.

At the Portable Comfort Control

1. Press and hold the blank space (or arrow) in the lower

right hand corner of the screen until the display changes

(hold for about 4 seconds).

Fig. 316.

2. Press REMOVE, then YES to disconnect from the old

thermostats.

3. To reconnect the thermostat, go to “Linking RedLINK™

Accessories” beginning on page 16.

At the Indoor Sensor, RedLINK Internet

Gateway, Entry/Exit Remote, Vent-Filter

Boost Remote or TrueSTEAM Wireless

Adapter

1. Press and hold the CONNECT button on the accessory

until the status light glows amber (hold for about 10 sec-

onds).

2. To reconnect the thermostat, go to “Linking RedLINK™

Accessories” beginning on page 16.

REPLACING AN EQUIPMENT

INTERFACE MODULE

When you replace an EIM, you must reset the RedLINK

accessories before connecting them to the new thermostat.

Follow the instructions below:

At the thermostat

1. Press MENU, scroll down and select Installer Options,

enter the password (Date Code) when prompted, scroll

down and select Wireless Manager, scroll down and

select Remove Device, then select This Thermostat.

2. Follow the prompts on the screen to connect the thermo-

stat to the new EIM.

At the Portable Comfort Control

1. Press and hold the blank space (or arrow) in the lower

right hand corner of the screen until the display changes

(hold for about 4 seconds). See Fig. 316.

2. Press REMOVE, then YES to disconnect from the old

thermostats. To reconnect the thermostat, go to “Linking

RedLINK™ Accessories” beginning on page 16.

At the Indoor Sensor, RedLINK Internet

Gateway, Entry/Exit Remote, Vent-Filter

Boost Remote or TrueSTEAM Wireless

Adapter

1. Press and hold the CONNECT button on the accessory

until the status light glows amber (hold for about 10 sec-

onds).

2. To reconnect the thermostat, go to “Linking RedLINK™

Accessories” beginning on page 16.

Press and hold

the blank space

(or arrow may be

present)

Advertising
This manual is related to the following products: