Radiant Heat

Cycles Per Hour -

Stage 2

1 to 12 CPH

3

Both

No

ISU 3010 Temperature Control Options

must be set to Advanced to view or adjust

cycle rate.

This ISU is only displayed when ISU 2010

Heating Equipment Type is Geothermal

Radiant Heat.

The thermostat automatically defaults to

the recommended setting for Geothermal

Radiant Heat (3 CPH).

Cycle rate limits the maximum number of

times the system can cycle in a 1 hour

period measured at a 50% load. For

example, when set to 3 CPH, at a 50% load,

the most the system will cycle is 3 times

per hour (10 minutes on, 10 minutes off).

The system cycles less often when load

conditions are less than or greater than a

50% load.

3140

Cool / Compressor

Cycles Per Hour -

Stage 1

Note: “Stage 1" is

not displayed if

there is only 1

stage.

1 to 6 CPH

3

Both

No

ISU 3010 Temperature Control Options

must be set to Advanced to view or adjust

cycle rate.

This ISU is only displayed when ISU 2070

Cool / Compressor Stages is set to 1 stage.

Cycle rate limits the maximum number of

times the system can cycle in a 1 hour

period measured at a 50% load. For

example, when set to 3 CPH, at a 50% load,

the most the system will cycle is 3 times

per hour (10 minutes on, 10 minutes off).

The system cycles less often when load

conditions are less than or greater than a

50% load.

3140

Cool / Compressor

Cycles Per Hour -

Stage 2

1 to 6 CPH

3

Both

No

ISU 3010 Temperature Control Options

must be set to Advanced to view or adjust

cycle rate.

This ISU is only displayed when ISU 2070

Cool / Compressor Stages is set to 2

stages.

Cycle rate limits the maximum number of

times the system can cycle in a 1 hour

period measured at a 50% load. For

example, when set to 3 CPH, at a 50% load,

the most the system will cycle is 3 times

per hour (10 minutes on, 10 minutes off).

The system cycles less often when load

conditions are less than or greater than a

50% load.

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes