THX9321 Thermostat Wiring Diagrams

Typical wiring of a 3-heat / 2-cool heat pump system with one

transformer.

Fig. 322. Prestige THX9321 and heat pump system with

one transformer.

Typical wiring of a 2-heat / 2-cool conventional system with one

transformer.

Fig. 323. Prestige THX9321 and 2-heat / 2-cool

conventional system with one transformer.

Typical wiring of a 3-heat / 2-cool heat pump system with two

transformers.

Fig. 324. Prestige THX9321 and heat pump system with

two transformers.

Typical wiring for geothermal radiant heat, geothermal forced-

air and backup heat with one transformer. See “Geothermal

Radiant Heat” on page 100.

Fig. 325. Prestige THX9321 and geothermal radiant heat,

geothermal forced-air and backup heat with one

transformer.

1 U1 and U2 terminals are dry contacts.
2 L/A terminal sends continuous output when thermostat is set to EM HEAT mode except when set up for Economizer or TOD.

See “Economizer Module Wiring Diagrams” beginning on page 151.

3 U1 or U2 terminals must be used for geothermal radiant heat (ISU 2010). Thermostat allows 2 stages of radiant heat—geother-

mal (stage 1) and boiler (stage 2).

4 “U” terminals are normally open dry contacts when set up for geothermal radiant heat. You must install a field jumper if radiant

heat is powered by system transformer. Do NOT install a field jumper if radiant heat has its own transformer.

5 Remove jumper if using separate transformers.
6 Connect the THP9045 Wiresaver Module to the K terminal in heating/cooling applications that do not have a common wire at the

thermostat. The K terminal cannot be used in heat-only applications. See THP9045 installation instructions for more information.

NOTE: For setup and operation, see “Geothermal Radiant Heat” beginning on page 100.

CHANGEOVER VALVE

BACKUP HEAT

COMPRESSOR STAGE 1

COMPRESSOR STAGE 2

FAN RELAY

COMPRESSOR MONITOR

OR ZONE PANEL

120

VAC

O/B

AUX/E

Y

Y2

G

L/A

K

C

Rc

R

U1

U1

U2

U2

24

VAC

Transformer

Thermostat

C
R

1

2

6

M32948A

HEAT STAGE 1

HEAT STAGE 2

COMPRESSOR STAGE 1

COMPRESSOR STAGE 2

FAN RELAY

120

VAC

W

W2

Y

Y2

G

A

K

C

Rc

R

U1

U1

U2

U2

24

VAC

Transformer

Thermostat

C
R

1

5

6

M32949A

3

1

CHANGEOVER VALVE

COMPRESSOR STAGE 1

COMPRESSOR STAGE 2

FAN RELAY

COMPRESSOR MONITOR

OR ZONE PANEL

120

VAC

O/B

AUX/E

Y

Y2

G

L/A

K

C

Rc

R

U1

U1

U2

U2

24

VAC

Air Handler

Transformer

120

VAC

24

VAC

Backup Heat

Transformer

C
R

R

C

Thermostat

BACKUP HEAT

1

2

6

M32950A

CHANGEOVER VALVE

BACKUP HEAT

COMPRESSOR STAGE 1

COMPRESSOR STAGE 2

FAN RELAY

COMPRESSOR MONITOR

OR ZONE PANEL

120

VAC

O/B

AUX/E

Y

Y2

G

L/A

K

C

Rc

R

U1

U1

U2

U2

24

VAC

Transformer

Thermostat

C
R

GEOTHERMAL

RADIANT

HEAT

STAGE 1

3

2

4

6

M32951A