Honeywell PRESTIGE THX9321 User Manual

Page 55

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

55

68-0311—02

8050

Humidification -

Window Protection

Off
On

Off

Both

No

Requires an optional outdoor sensor.

Off: The thermostat controls the humidity

level to the user's desired humidity setting.

Frost or condensation may appear on

windows.

On: The thermostat prevents frost or

condensation on windows by not allowing

the humidity to go above the “Window

Limit” when it is controlling the humidifier.

The “Window Limit” is based on the

current outdoor temperature and the user's

window protection setting. The “Window

Limit” is displayed on the user's

humidification screen. See “Window

Protection” beginning on page 102.

8060

System Modes

Allowing

Humidification

Check box on screen for each:
Heat
Cool
Off

Heat

Default varies

based on

heating/cooling

equipment

selected

Both

No

Click boxes on screen to select which

system modes allow humidification. If a

box is NOT checked, the thermostat will

NOT allow humidification to operate in that

mode.

Heat: Includes Heat, Emergency Heat and

Auto. If the system is in Auto mode, the

thermostat will allow humidification if the

last call was for heat.

Cool: Includes Cool and Auto. If the system

is in Auto mode, the thermostat will allow

humidification if the last call was for cool. A

discharge air temperature sensor is

required to humidify in the Cool mode.

Off: The thermostat will allow

humidification when the system setting is

Off.

See “Set up Humidification” beginning on

page 102.

8070

Humidification

Control

Humidify Only when Heat is On

Humidify Only when Fan is On

Humidify on Demand:
Thermostat Controls Fan

Humidify on Demand:
Humidifier Controls Fan

Defaults to

Humidify Only

when Heat is

On

when ISU 8000

Humidifier

Type is Bypass

or Fan Powered

Defaults to

Humidify on

Demand:

Thermostat

Controls Fan

when ISU 8000

Humidifier

Type is Steam

Both

No

Humidify Only when Heat is On: The

thermostat turns on the humidifier only if

the heat is currently running.

Humidify Only when Fan is On: The

thermostat turns on the humidifier only if

the fan is currently running.

Humidify on Demand - Thermostat

Controls Fan: The thermostat turns on the

humidifier and the fan when humidification

is needed.

Humidify on Demand - Humidifier Controls

Fan: The thermostat turns on the humidifier

when humidification is needed and the

humidifier controls the fan.

8080

Humidifier Lockout

Humidifier Allowed when Cool is

Running

Humidifier Not Allowed when Cool

is Running

Humidifier

Allowed when

Cool is

Running

Both

No

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes

Advertising