Dehumidification Away Mode

Dehumidification Away Mode for a commercial application is

identical to Dehumidification Away Mode for a residential

application. See “Dehumidification Away Mode” on page 107

and “Set up Dehumidification Away Mode” beginning on

page 108.

Control Dehumidification Level

1. Press MENU, then scroll to select Dehumidification.

2. Press Auto to use the dehumidifier or cooling system to

maintain your desired humidity level.

3. Press Off to turn off dehumidification.

4. Move the slider bar to the humidity level you prefer, then

press DONE. The dehumidification setting range is

40–80% in 5% increments.

5. If your air conditioner is used to control humidity, the

thermostat may use the following methods to maintain

your desired humidity:

• Cool from 1° to 5° F lower than your temperature

setting.

• Run cooling for the minimum “on” time to reduce

humidity.

• Run cooling and heating at the same time to reduce

humidity without lowering the temperature.

6. Press MORE SETTINGS to review or change settings for

the dehumidifier filter timer.

NOTE: If humidification and dehumidification are setup

to operate in the same system mode (Heat, Cool,

Off) and you are sensing humidity from one loca-

tion, the thermostat will automatically enforce a

15% deadband between the humidification and

dehumidification settings. The thermostat will

automatically switch between humidification and

dehumidification to maintain the desired humidity

level.

If humidification and dehumidification are setup

to operate in the same system mode (Heat, Cool,

Off) and you are sensing humidity from two differ-

ent locations using a remote wireless indoor sen-

sor (for example, main level and crawl space), the

thermostat will allow humidification and dehumid-

ification to operate at the same time, and there is

no deadband between humidification and dehu-

midification settings.

Ventilation

The thermostat can be set for the following ventilation types:

(ISU 10000)

• ERV/HRV

• Passive (Fan Only)

• Fresh Air Damper

Ventilation Control Methods (ISU 10050)

Ventilation can be setup to meet either ASHRAE or Percent On

Time settings. To meet these settings, the thermostat will

ventilate during calls for heat, cool, and fan. If the required

ventilation has not been achieved for ASHRAE or Percent On

Time, the thermostat will force the ventilation equipment on.

ASHRAE

The thermostat operates ventilation equipment to meet the

ASHRAE 62.2 ventilation standard based on CFM, number

of bedrooms, and square footage of the house. ASHRAE

62.2 can only be met if the ventilation equipment is running.

If the ventilation equipment is off for any reason (outdoor

ventilation lockouts, set up to turn Off during Sleep period,

turned off by user, etc.), ASHRAE 62.2 is not met during

those times. See ISU 10125 to select a Ventilation Priority.

Percent On Time

The thermostat operates ventilation equipment based on a

percentage entered in the installer setup (ISU 10120). For

example if Percent On Time is set to 50%, the ventilation

equipment will run at random times during a 1 hour period

until it reaches a 50% run time (approximately 30 minutes).

Default setting is 30%. Range is 10% to 100% in 10%

increments.

Press MENU

Scroll to select DEHUMIDIFICATION

Set humidity to desired level

Press to review filter timer