Honeywell PRESTIGE THX9321 User Manual

Page 64

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

68-0311—02

64

13030 Allow Delta T

Diagnostics During

Dehumidification

No
Yes

Yes

Both

Yes

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

No: The thermostat does NOT monitor

Delta T of the system during a call for

dehumidification.

Yes*: The thermostat monitors Delta T of

the system during a call for

dehumidification.

* Default is Yes for Dehumidifiers and A/C

with High Speed Fan. The thermostat does

NOT monitor Delta T Diagnostics during

dehumidification if it is setup for A/C with

Low Speed Fan, Hot Gas Bypass or Reheat.

13040 Allow Delta T

Diagnostics During

Ventilation

No
Yes

Yes

Both

Yes

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

No: The thermostat does NOT monitor

Delta T of the system during a call for

ventilation.

Yes: The thermostat monitors Delta T of the

system during a call for ventilation.

13050 Allow Heat Delta T

Diagnostics when

Indoor

Temperature is

[Indoor

Temperature

Range]

Minimum Setting

No Limit
35° F to 115° F (in 5° F

increments)

No Limit

(Always)

Both

Yes

This ISU only applies to Heating.

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

The thermostat monitors Delta T of the

system ONLY when the indoor temperature

is within a certain range. Set to No Limit to

monitor Delta T during all indoor

temperature conditions.

13050

Maximum Setting

No Limit
40° F to 120° F (in 5° F

increments)

No Limit

(Always)

Both

Yes

13060 Allow Heat Delta T

Diagnostics when

Indoor Humidity is

[Indoor Humidity

Range]

Minimum Setting

No Limit
0% to 95% (in 5% increments)

No Limit

(Always)

Both

Yes

This ISU only applies to Heating.

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

The thermostat monitors Delta T of the

system ONLY when the indoor humidity is

within a certain range. Set to No Limit to

monitor Delta T during all indoor humidity

conditions.

13060

Maximum Setting

No Limit
5% to 100% (in 5% increments)

No Limit

(Always)

Both

Yes

13070 Allow Heat Delta T

Diagnostics when

Outdoor

Temperature is

[Outdoor

Temperature

Range]

Minimum Setting

No Limit
-50° F to 135° F (in 5° F

increments)

No Limit

(Always)

Both

Yes

This ISU only applies to Heating.

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

The thermostat monitors Delta T of the

system ONLY when the outdoor

temperature is within a certain range. Set

to No Limit to monitor Delta T during all

outdoor temperature conditions.

13070

Maximum Setting

No Limit
-45° F to 140° F (in 5° F

increments)

No Limit

(Always)

Both

Yes

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes