THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

49

68-0311—02

5040

Which Sensors will

be used for

TEMPERATURE

Control? (Multiple

Sensors are

Averaged)

Thermostat (Internal)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)

(Up to 6 Remote Sensors)

Sensors are

Averaged

(Internal and

Remote)

Both

No

Select the sensors to be used for

temperature control. If you select more

than one, the thermostat will average the

temperature readings from each sensor.

See “Remote Indoor Sensors” beginning

on page 130.

5050

What Terminals are

Wired to the

Outdoor

Temperature

Sensor?

None
S1
S2
S3
S4

None

Both

Yes

Wired Sensors requires an EIM (Equipment

Interface Module).

5070

What Terminals are

Wired to the Return

Air Temperature

Sensor?

None
S1
S2
S3
S4

None

Both

Yes

Wired Sensors requires an EIM (Equipment

Interface Module).

5080

Return Air

Temperature

Sensor Type

10K
20K

10K

Both

Yes

Wired Sensors requires an EIM (Equipment

Interface Module).

Select 10K or 20K based on the sensor

installed. Refer to resistance values below:

50062329-001 = 10K ohm

32005180-002 = 10K ohm

C7735A1000 = 10K ohm

C7770A = 20K ohm

C7041 = 20K ohm

5090

What Terminals are

Wired to the

Discharge Air

Temperature

Sensor?

None
S1
S2
S3
S4

None

Both

Yes

Wired Sensors requires an EIM (Equipment

Interface Module).

5100

Discharge Air

Temperature

Sensor Type

10K
20K

10K

Both

Yes

Wired Sensors requires an EIM (Equipment

Interface Module).

Select 10K or 20K based on the sensor

installed. Refer to resistance values below:

50062329-001 = 10K ohm

32005180-002 = 10K ohm

C7735A1000 = 10K ohm

C7770A = 20K ohm

C7041 = 20K ohm

5110

A-Coil Low

Temperature Cutoff

Off
35° F to 65° F (in 5° F increments)

Off

Both

Yes

If an optional Discharge Air Temperature

sensor is used, this feature can help

prevent icing on the air conditioning A-Coil.

When temperature reaches the limit you

set, compressor(s) will shutoff while the

system fan continues to run, until the

temperature rises to a safe level.

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes