Control humidification level – Honeywell PRESTIGE THX9321 User Manual

Page 104

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

68-0311—02

104

7. Set the desired lockout option. See Fig. 214.

Fig. 214.

NOTE: ISU 10140 gives the option to lockout ventila-

tion during calls for humidification. This helps

maintain the desired humidity level.

Control Humidification Level

1. Press MENU, then scroll to select Humidification.

2. Press Auto to use the humidifier to maintain your desired

humidity level.

3. Press Off to turn off the humidifier.

4. Move the slider bar to the humidity level you prefer, then

press DONE. The humidification setting range is

10–60% in 5% increments.

5. Press MORE SETTINGS if frost or condensation

appears on windows. A lower number adjusts humidity to

help prevent these problems. Use a higher number if

indoor air is too dry.

6. To adjust the Window Protection setting, press More Set-

tings from the Humidification screen. Window Protection

is set on a scale from 1-10. A setting of “1” represents

poorly insulated windows and a setting of “10” repre-

sents well insulated windows. A lower number automati-

cally reduces the humidity to help prevent frost or

condensation on your windows. Use a higher number if

indoor air seems too dry. To prevent frost/condensation

on your windows during cold outdoor temperatures,

poorly insulated windows require a lower Window Pro-

tection setting, which will limit how much your humidifier

can run.

7. After you set the Window Protection setting, check for

frost/condensation on your windows in the morning. If

frost/condensation is present, adjust the Window Protec-

tion setting to the next lowest number and check for frost/

condensation on your windows the next morning. Con-

tinue to adjust the Window Protection setting to a lower

number until frost/condensation is no longer present.

NOTE: The Window Protection option is only available if

an optional outdoor sensor is installed.

NOTE: If humidification and dehumidification are setup

to operate in the same system mode (Heat, Cool,

Off) and you are sensing humidity from one loca-

tion, the thermostat will automatically enforce a

15% deadband between the humidification and

dehumidification settings. The thermostat will

automatically switch between humidification and

dehumidification to maintain the desired humidity

level.

If humidification and dehumidification are setup

to operate in the same system mode (Heat, Cool,

Off) and you are sensing humidity from two differ-

ent locations using a remote wireless indoor sen-

sor, the thermostat will allow humidification and

dehumidification to operate at the same time, and

there is no deadband between humidification and

dehumidification settings.

Fig. 215.

Press MENU

Scroll to select HUMIDIFICATION

Set humidity to desired level

Window Protection

limits the amount of

humidity to prevent

frost or condensation

on windows

Press More Settings to set:

• Window Protection Setting

• Review humidifier pad or

clean tank / water filter

timer