Delta t alerts and utility saver switches, Data logs – Honeywell PRESTIGE THX9321 User Manual

Page 91

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

91

68-0311—02

Delta T Alerts are also displayed for performance related

issues such as dirty air filter, blocked registers, loss of

refrigerant, dirty a-coil, frozen a-coil, cracked heat exchanger,

dirty burners, burners need adjustment, etc.

Alerts are displayed to the user on the home screen. See Fig.

160 for an example.

Fig. 160.

When the user presses the alert for more information, the

Notification screen is displayed, prompting them to perform

some basic troubleshooting and, if the problem persists,

contact their dealer. See Fig. 161 as an example.

Fig. 161.

Alerts are also recorded in the Alerts Log. See “Data Logs”

beginning on page 91.

Delta T Alerts and Utility Saver

Switches

For systems that might be interrupted by a utility saver switch

(conventional cooling and heat pumps in the heat and cool

mode), the thermostat will ask if a utility saver switch is

installed and provide an option to the user to turn off

diagnostics temporarily while power is interrupted by the utility

company. Diagnostics can be turned off for 1-14 days.

Fig. 162.

Fig. 163.

Data Logs

The Data Logs collect system information that can help point a

service technician in the right direction when troubleshooting.

When accessing the Data Logs, the installer can turn off each

log, delete current log entries, and save Data Logs to a

memory stick via the USB port. See “Using the Data Logs”

beginning on page 94 and “To save a Data Log to a memory

stick” beginning on page 95 for more information.

Data Logs include the Alerts Log, User Interactions Log, and

Performance Logs.