52

6100

Water Leak Alert

Dry Contact Setup

Normally Open
Normally Closed

Normally Open Both

Yes

Dry Contact Alerts require an EIM

(Equipment Interface Module).

Choose an option appropriate for the type

of device installed:

Normally Open: The Dry Contact device is

normally open and will close when the

device detects water.

Normally Closed: The Dry Contact device is

normally closed and will open when the

device detects water.

6110

What Terminals are

Wired to the

System Shutdown

Alert Dry Contact?

None
S1
S2
S3
S4

None

Both

Yes

Dry Contact Alerts require an EIM

(Equipment Interface Module).

6120

System Shutdown

Alert Dry Contact

Setup

Normally Open
Normally Closed

Normally Open Both

Yes

Dry Contact Alerts require an EIM

(Equipment Interface Module).

Choose an option appropriate for the type

of device installed:

Normally Open: The Dry Contact device is

normally open and will close when the

device is activated.

Normally Closed: The Dry Contact device is

normally closed and will open when the

device is activated.

6130

What Terminals are

Wired to the

Service Needed

Alert Dry Contact?

None
S1
S2
S3
S4

None

Both

Yes

Dry Contact Alerts require an EIM

(Equipment Interface Module).

6140

Service Needed

Alert Dry Contact

Setup

Normally Open
Normally Closed

Normally Open Both

Yes

Dry Contact Alerts require an EIM

(Equipment Interface Module).

Choose an option appropriate for the type

of device installed:

Normally Open: The Dry Contact device is

normally open and will close when the

device is activated.

Normally Closed: The Dry Contact device is

normally closed and will open when the

device is activated.

6150

What Terminals are

Wired to the Fan

Failure Alert Dry

Contact?

None
S1
S2
S3
S4

None

Both

Yes

Dry Contact Alerts require an EIM

(Equipment Interface Module).

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes