Honeywell PRESTIGE THX9321 User Manual

Page 56

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

68-0311—02

56

8100

Clean Tank / Water

Filter Replacement

Reminder

Off
60 Run Time Days
90 Run Time Days
6 Calendar Months
12 Calendar Months

Off

Both

No

This ISU is only displayed if ISU 8000

Humidifier Type is Steam.

Run Time Days are not shown if ISU 8000

Humidifier Type is set to None.

8100

Humidifier Pad

Replacement

Reminder

Off
60 Run Time Days
90 Run Time Days
6 Calendar Months
12 Calendar Months

Off

Both

No

This ISU is only displayed if ISU 8000

Humidifier Type is Bypass or Fan Powered.

Run Time Days are not shown if ISU 8000

Humidifier Type is set to None.

9000

Dehumidification

Equipment

Residential:
None
A/C with Low Speed Fan
A/C with High Speed Fan
Whole House Dehumidifier

Commercial:
None
A/C with Low Speed Fan
A/C with High Speed Fan
Hot Gas Bypass
Dehumidifier

None

Both

No

See “Dehumidification - Residential”

beginning on page 105 or

“Dehumidification - Commercial”

beginning on page 109.

9010

Which Sensor will

be used for

Dehumidification

Control?

Thermostat (Internal)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)

(Up to 6 Remote Sensors)

Thermostat

(Internal)

Both

No

Select a sensor to control dehumidification

(thermostat or an optional remote sensor).

If multiple sensors are installed, you can

use a different sensor for humidification

control. See “Dehumidification control”

beginning on page 130.

Note: Humidity sensing cannot be

averaged.

9020

Which Indoor

Humidity Sensor

should be

displayed on the

Home Screen?

Humidification Sensor
Dehumidification Sensor

Humidification

Sensor

Both

No

This ISU is only displayed when separate

humidity sensors are used to control

humidification and dehumidification. Only

one of the sensors can be displayed on the

home screen. Select either the

Humidification Sensor or the

Dehumidification Sensor.

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes

Advertising
This manual is related to the following products: