THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

68-0311—02

28

2170

What Terminals are

Wired to Backup

Heat - Stage 2?

None
U1
U2

Default varies

based on

previous

selections

Both

No

THX9321 Thermostat Only:

This ISU is only displayed on the THX9321

thermostat when it is wired directly to the

equipment (Equipment Interface Module is

NOT used).

The thermostat can support up to 2 backup

heat stages for heat pump applications.

When there are 2 backup heat stages,

backup heat stage 2 must be wired to U1 or

U2.

U1 and U2 are normally open dry contacts

when configured for a stage of Heat. U1

and U2 require power from a system

transformer or a separate transformer.

2180

Backup Heat Type

Electric Forced Air
Standard Efficiency Gas Forced Air
High Efficiency Gas Forced Air
Oil Forced Air
Hot Water Fan Coil
Hot Water Radiant Heat
Other

Electric Forced

Air

Both

No

This ISU is only displayed when ISU 2010

Heating Equipment Type is Air to Air Heat

Pump, Geothermal Heat Pump or

Geothermal Radiant Heat and there is at

least one stage of backup heat.

See “Heat Pump and Backup Heat

Operation” beginning on page 100.

2190

External Fossil Fuel

Kit

Thermostat Controls Backup Heat
External Fossil Fuel Kit Controls

Backup Heat

Thermostat

Controls

Backup Heat

Both

No

This ISU is only displayed when ISU 2010

Heating Equipment Type is Air to Air Heat

Pump, Geothermal Heat Pump or

Geothermal Radiant Heat and ISU 2180

Backup Heat Type is Standard Efficiency

Gas Forced Air, High Efficiency Gas

Forced Air or Oil Forced Air.

2200

Backup Heat

Operation

NOT allowed to Run with Heat

Pump
Allowed to Run with Heat Pump

Default varies

based on

previous

selections

Both

No

This ISU is only displayed when ISU 2010

Heating Equipment Type is Air to Air Heat

Pump, Geothermal Heat Pump or

Geothermal Radiant Heat and ISU 2180

Backup Heat Type is Hot Water Fan Coil or

Other.

Not Allowed to Run with Heat Pump: The

thermostat turns off the heat pump when it

calls for backup heat.

Allowed to Run with Heat Pump: The

thermostat keeps the heat pump on when it

calls for backup heat.

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes