Honeywell PRESTIGE THX9321 User Manual

Page 111

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

111

68-0311—02

2. If optional remote wireless indoor sensors are installed,

you can choose which sensor you want to use for dehu-

midification control. For example, you can use one sen-

sor for humidification control, and another for

dehumidification. See “Wireless Indoor Sensor” begin-

ning on page 130 for more information.

Fig. 242.

3. If you are sensing humidity from two separate locations

(one for humidification and another for dehumidification),

you can select which humidity reading to display on the

home screen. See “Wireless Indoor Sensor” beginning

on page 130 for more information.

Fig. 243.

4. Select the terminals wired to the Dehumidifier. See Fig.

244.

Fig. 244.

5. Select the system mode(s) to allow dehumidification.

See Fig. 245.

NOTE:

Heat includes Heat, Emergency Heat and Auto.

If the system is in Auto mode, the thermostat

will allow dehumidification if the last call was for

heat.

Cool includes Cool and Auto. If the system is in

Auto mode, the thermostat will allow dehumidifi-

cation if the last call was for cool.

Fig. 245.

6. Set Dehumidifier Fan Control settings. See Fig. 246.

Thermostat Controls Fan

Thermostat turns on the dehumidifier and the fan

when dehumidification is needed.

Equipment Controls Fan

Thermostat turns on the dehumidifier when

dehumidification is needed. The fan is controlled by

the equipment.

Fig. 246.

7. Set the desired lockout option. See Fig. 247.

Fig. 247.

NOTE: ISU 10140 gives the option to lockout ventila-

tion on calls for dehumidification. This helps

maintain the desired humidity level.