5. Select whether the U1, U2, or U3 terminals are Normally

Open or Normally Closed. See Fig. 220.

Normally Open – contacts are normally open and will

close during a call for dehumidification

Normally Closed – contacts are normally closed and

will open during a call for dehumidification.

Fig. 220.

6. Set the Overcooling Limit. See Fig. 221. Options:

• 0 °F to 3 °F (A/C with Low Speed Fan)

• 1 °F to 3 °F (A/C with High Speed Fan)

Fig. 221.

NOTE: ISU 10140 gives the option to lockout ventila-

tion on calls for dehumidification. This helps

maintain the desired humidity level.

Dehumidification using a Whole House

Dehumidifier

The Whole House Dehumidifier option requires a dedicated

unit for dehumidification. The thermostat can be set to control

dehumidification in all modes (Heat, Off, Cool [ISU 9120]).

Set up Dehumidification With Whole House

Dehumidifier

Some screens shown in this section may not appear on the

thermostat, depending on how you set up dehumidification.

1. Select the Dehumidification Equipment in ISU 9000. See

Fig. 222.

Fig. 222.

2. If optional remote wireless indoor sensors are installed,

you can choose which sensor you want to use for dehu-

midification control. For example, you can use one sen-

sor for humidification control, and another for

dehumidification. See “Wireless Indoor Sensor” begin-

ning on page 130 for more information.

Fig. 223.

3. If you are sensing humidity from two separate locations

(one for humidification and another for dehumidification),

you can select which humidity reading to display on the

home screen. See “Wireless Indoor Sensor” beginning

on page 130 for more information.