Zoning and Ventilation

Fig. 357. Ventilation with zoning.

Setting up Ventilation Control on Prestige or Prestige IAQ

Select the terminals wired to the ventilator at ISU 10020 (U1, U2, U3). In Fig. 357, the ventilator is wired to U1. To ventilate in all

zones, set ISU 10060 Ventilation Fan Control to Equipment Controls Fan.

TrueDRY dehumidifier with Zoning

Fig. 358. Prestige IAQ with an HZ432 zone panel and a TrueDRY dehumidifier.

Setting up Dehumidification Control on Prestige or Prestige IAQ

Select the terminals wired to the dehumidifier at ISU 9040 (U1, U2, U3). In Fig. 358, the dehumidifier is wired to U1. To dehumidify

in all zones, set ISU 9130 Dehumidifier Fan Control to Equipment Controls Fan.

RH
RC

W1/E

W2
W3

Y1
Y2

G
O

B

DS/BK

MCR31523

EQ

UIPMENT

C

R

W

Y

G

FURNACE

TrueZONE PANEL

PRESTIGE

IAQ EIM

ERV/HRV

INTERLOCK B G R

AUX W B G R

2

2

1

1

SELECT THE TERMINALS WIRED TO THE VENTILATOR AT ISU 10020 (U1, U2, U3).
TO VENTILATE IN ALL ZONES, SET ISU 10060 VENTILATION FAN CONTROL TO EQUIPMENT CONTROLS FAN.

FOR ALL ZONE PANEL WIRING NOT SHOWN IN THIS DIAGRAM, SEE OTHER ZONING DIAGRAMS OR ZONE PANEL
INSTALLATION INSTRUCTIONS.

RH
RC

W1/E

W2
W3

Y1
Y2

G
O

B

DS/BK

MCR31524

EQ

UIPMENT

C

R

W

Y

G

FURNACE

TrueZONE PANEL

PRESTIGE

IAQ EIM

TrueDRY DEHUMIDIFIER

DHUM R FAN C

GT Rf Gf

2

2

1

1

SELECT THE TERMINALS WIRED TO THE VENTILATOR AT ISU 9040 (U1, U2, U3).
TO VENTILATE IN ALL ZONES, SET ISU 9130 DEHUMIDIFIER FAN CONTROL TO EQUIPMENT CONTROLS FAN.

FOR ALL ZONE PANEL WIRING NOT SHOWN IN THIS DIAGRAM, SEE OTHER ZONING DIAGRAMS OR ZONE PANEL
INSTALLATION INSTRUCTIONS.