THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

65

68-0311—02

13080 Allow Heat Delta T

Diagnostics when

Outdoor Humidity

is [Outdoor

Humidity Range]

Minimum Setting

No Limit
0% to 95% (in 5% increments)

No Limit

(Always)

Both

Yes

This ISU only applies to Heating.

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

The thermostat monitors Delta T of the

system ONLY when the outdoor humidity is

within a certain range. Set to No Limit to

monitor Delta T during all outdoor humidity

conditions.

13080

Maximum Setting

No Limit
5% to 100% (in 5% increments)

No Limit

(Always)

Both

Yes

13090 Allow Backup Heat

Delta T Diagnostics

when Indoor

Temperature is

[Indoor

Temperature

Range]

Minimum Setting

No Limit
35° F to 115° F (in 5° F

increments)

No Limit

(Always)

Both

Yes

This ISU only applies to Backup Heat.

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

The thermostat monitors Delta T of the

system ONLY when the indoor temperature

is within a certain range. Set to No Limit to

monitor Delta T during all indoor

temperature conditions.

13090

Maximum Setting

No Limit
40° F to 120° F (in 5° F

increments)

No Limit

(Always)

Both

Yes

13100 Allow Backup Heat

Delta T Diagnostics

when Indoor

Humidity is [Indoor

Humidity Range]

Minimum Setting

No Limit
0% to 95% (in 5% increments)

No Limit

(Always)

Both

Yes

This ISU only applies to Backup Heat.

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

The thermostat monitors Delta T of the

system ONLY when the indoor humidity is

within a certain range. Set to No Limit to

monitor Delta T during all indoor humidity

conditions.

13100

Maximum Setting

No Limit
5% to 100% (in 5% increments)

No Limit

(Always)

Both

Yes

13110 Allow Backup Heat

Delta T Diagnostics

when Outdoor

Temperature is

[Outdoor

Temperature

Range]

Minimum Setting

No Limit
-50° F to 135° F (in 5° F

increments)

No Limit

(Always)

Both

Yes

This ISU only applies to Backup Heat.

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

The thermostat monitors Delta T of the

system ONLY when the outdoor

temperature is within a certain range. Set

to No Limit to monitor Delta T during all

outdoor temperature conditions.

13110

Maximum Setting

No Limit
-45° F to 140° F (in 5° F

increments)

No Limit

(Always)

Both

Yes

13120 Allow Backup Heat

Delta T Diagnostics

when Outdoor

Humidity is

[Outdoor Humidity

Range]

Minimum Setting

No Limit
0% to 95% (in 5% increments)

No Limit

(Always)

Both

Yes

This ISU only applies to Backup Heat.

This ISU is only displayed when ISU 13015

Set Advanced Diagnostic Options is set to

Yes.

The thermostat monitors Delta T of the

system ONLY when the outdoor humidity is

within a certain range. Set to No Limit to

monitor Delta T during all outdoor humidity

conditions.

13120

Maximum Setting

No Limit
5% to 100% (in 5% increments)

No Limit

(Always)

Both

Yes

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes