68-0311—02

9130

Dehumidifier Fan

Control

Thermostat Controls Fan
Equipment Controls Fan

Thermostat

Controls Fan

Both

No

This ISU is only displayed when ISU 9000

Dehumidification Equipment is set to

Dehumidifier.

Thermostat Controls Fan: The thermostat

turns on the dehumidifier and the fan when

dehumidification is needed.

Equipment Controls Fan: The thermostat

turns on the dehumidifier when

dehumidification is needed. The fan is

controlled by the equipment.

9140

Dehumidifier

Lockout

Dehumidifier Allowed when Cool

is Running

Dehumidifier Not Allowed when

Cool is Running

Dehumidifier

Allowed when

Cool is

Running

Both

No

This ISU is only displayed when ISU 9000

Dehumidification Equipment is set to

Dehumidifier.

Dehumidifier Allowed when Cool is

Running: Dehumidifier can run when the

cooling system is on.

Dehumidifier Not Allowed when Cool is

Running: Dehumidifier can NOT run when

the cooling system is on.

9180

Dehumidification

Away Mode

Not Allowed
Allowed

Not Allowed

Both

No

This ISU is NOT displayed when ISU 9000

Dehumidification Equipment is None.

ISU 9190 to 9200 are only displayed when

ISU 9180 Dehumidification Away Mode is

Allowed.

See “Dehumidification Away Mode”

beginning on page 107.

9190

Dehumidification

Away Mode - Fan

Control

Automatic
On
Circulate

Automatic

Both

No

The On and Circulate settings may re-

introduce humidity into the living space.

9200

Dehumidification

Away Mode - Low

Limit Temperature

Setting

70° F to 80° F

76° F

Both

No

If the cooling system is used to control

humidity while Dehumidification Away

Mode is active, the thermostat allows the

cooling system to lower the indoor air to

the Low Limit Temperature Setting to reach

the dehumidification setting at ISU 9200.

9200

Dehumidification

Away Mode -

Temperature

Setting

70° F to 99° F

85° F

Both

No

The temperature maintained while

Dehumidification Away Mode is active and

the desired humidity level is satisfied.

9200

Dehumidification

Away Mode -

Dehumidification

Setting

40% to 70% (in 5% increments)

65%

Both

No

The desired humidity level while

Dehumidification Away Mode is active.

9210

Dehumidifier Filter

Replacement

Reminder

Off
30, 60, Calendar Days
3 to 12 Calendar Months (in 1

month increments)

Off

Both

No

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes

Advertising