Honeywell PRESTIGE THX9321 User Manual

Page 58

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

68-0311—02

58

9080

Dehumidification

Control

Basic

Minimum On Time

High Humidity Comfort Reset

High Humidity Comfort Reset with

Minimum On Time

Reheat

Reheat with Minimum On Time

Basic

Commercial No

See “Dehumidification - Commercial”

beginning on page 109.

9090

Dehumidification

Minimum On Time

5 to 15 minutes

10 minutes

Commercial No

This option ensures that the compressor

runs long enough to effectively reduce

humidity when the cooling equipment is

cycled on. The compressor will run for the

“minimum on time” you set until the

desired humidity level is reached.

9100

High Humidity

Comfort Reset

Setting

1° F to 5° F

2° F

Commercial No

The thermostat uses the cooling system to

reduce humidity by lowering the

temperature up to 5° F below the current

cool setpoint until the desired humidity

level is reached.

The thermostat keeps the temperature

below the cooling setpoint until the desired

humidity level is reached.

9120

System Modes

Allowing

Dehumidification

Check box on screen for each:
Heat
Cool
Off

Cool

Default varies

based on

heating/cooling

equipment

selected

Both

No

This ISU is only displayed when ISU 9000

Dehumidification Equipment is set to

Dehumidifier.

Click boxes on screen to select which

system modes allow dehumidification. If a

box is NOT checked, the thermostat will

NOT allow dehumidification to operate in

that mode.

Heat: Includes Heat, Emergency Heat and

Auto. If the system is in Auto mode, the

thermostat will allow dehumidification if

the last call was for heat.

Cool: Includes Cool and Auto. If the system

is in Auto mode, the thermostat will allow

dehumidification if the last call was for

cool.

Off: The thermostat will allow

dehumidification when the system setting

is Off.

See “Dehumidification - Residential”

beginning on page 105 or

“Dehumidification - Commercial”

beginning on page 109.

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes

Advertising