Set up Dehumidification Away Mode

1. Select Allowed at ISU 9180. See Fig. 231.

Fig. 231.

2. Set Fan Control settings. See Fig. 232.

• On: Fan is always on.

• Automatic: Fan runs only when cooling system is on.

• Circulate: Fan runs randomly, about 35% of the time.

Fig. 232.

3. Set temperature and dehumidification settings. See Fig.

234.

Low Limit Temperature Setting

If the cooling system is used to control humidity while

Dehumidification Away Mode is active, the thermostat

allows the cooling system to lower the indoor air to the

Low Limit Temperature Setting to reach the

Dehumidification Setting at ISU 9200.

Temperature Setting

The temperature maintained while Dehumidification

Away Mode is active and the desired humidity level is

satisfied.

Dehumidification Setting

The desired humidity level while Dehumidification

Away Mode is active.

Fig. 233.

Control Dehumidification Level

1. Press MENU, then scroll to select Dehumidification.

2. Press Auto to use the dehumidifier or cooling system to

maintain your desired humidity level.

3. Press Off to turn off dehumidification.

4. Move the slider bar to the humidity level you prefer, then

press DONE. The dehumidification setting range is

40–80% in 5% increments.

NOTE: When set for A/C with Low Speed Fan or A/C

with High Speed Fan, an overcooling limit can

be set from 0 °F to 3 °F (ISU 9070). The ther-

mostat uses the cooling system to reduce

humidity by lowering the temperature up to 3° F

below the current cool setpoint until the desired

humidity level is reached.

5. Press MORE SETTINGS to review or change settings for

the dehumidifier filter timer.

NOTE: If humidification and dehumidification are setup

to operate in the same system mode (Heat, Cool,

Off) and you are sensing humidity from one loca-

tion, the thermostat will automatically enforce a

15% deadband between the humidification and

dehumidification settings. The thermostat will

automatically switch between humidification and

dehumidification to maintain the desired humidity

level.

If humidification and dehumidification are setup

to operate in the same system mode (Heat, Cool,

Off) and you are sensing humidity from two differ-

ent locations using a remote wireless indoor sen-

sor (for example, main level and crawl space), the

thermostat will allow humidification and dehumid-

ification to operate at the same time, and there is

no deadband between humidification and dehu-

midification settings.

Press MENU

Scroll to select DEHUMIDIFICATION

Set humidity to desired level

Press to review filter timer