Backup heat upstage timer, Multistage control – Honeywell PRESTIGE THX9321 User Manual

Page 99

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

99

68-0311—02

2. Default is Comfort. Adjust differentials as needed.

Fig. 195.

Backup Heat Upstage Timer

The Backup Heat Upstage Timer is available for any system

with 2 heating types and the Backup Heat Differential is set to

2 °F (1.0 °C) or higher.

Backup heat is not used unless the indoor temperature drops

to the Backup Heat Differential setting or the Backup Heat

Upstage Timer expires, whichever occurs first. The upstage

timer starts when the highest stage of the previous equipment

type turns on.

Backup Heat Upstage Timer options are Off, 30 minutes to 16

hours. Default is Off.

Fig. 196.

Multistage Control

Multistage Control keeps the high stage of the equipment

running until the desired setpoint is reached. This setting is

recommended for Geothermal Heat Pumps to allow the loop to

rest.

Select Yes to turn on this feature. Default is No.

Fig. 197.

Fig. 198.