68-0311—02

13170 Defrost Cycle

None
1 to 60 minutes (in 1 minute

increments)

10

Both

Yes

This ISU is only displayed if ISU 2010

Heating Equipment Type is Air to Air Heat

Pump.

Press the up/down arrows to set the

maximum time duration of a defrost cycle.

Check the heat pump documentation for

the defrost cycle time.

Note: The diagnostic algorithm detects

when the system goes into defrost based

on the measured Delta T of the system.

When the thermostat detects this change in

temperature, the thermostat will not

compare Delta T to the Minimum and

Maximum Delta T Fault Limits. After the

defrost cycle has ended, the thermostat will

resume monitoring Delta T of the system.

13180 Delta T Alert

Sensitivity

1 to 5

3

Both

Yes

See “Delta T Alert Sensitivity (ISU 13180).”

beginning on page 90.

13190 Display Delta T

Alerts to User

No
Yes

Yes

Both

Yes

No: The thermostat does NOT display a

Delta T alert to the user when a Delta T alert

is entered into the log.

Yes: The thermostat displays a Delta T alert

to the user when a Delta T alert is entered

into the log.

See “Delta T Alerts” beginning on page 90.

14000 Clock Format

12 hour
24 hour

12

Both

No

14010 Daylight Saving

Time

Off
On

On

Both

No

Set to Off in areas that do not follow

Daylight Saving Time.

14020 Indoor

Temperature

Display Offset

-3° F to 3° F (in 1° F increments)

0° F

Both

No

0° F - No difference in displayed

temperature and the actual room

temperature.

The thermostat displays up to 3°F (1.5°C)

lower or higher than the actual measured

temperature.

14020 Indoor Humidity

Display Offset

-12% to 12% (in 1% increments)

0%

Both

No

0% - No difference in displayed humidity

and the actual room humidity.

The thermostat displays up to 12% lower

or higher than the actual measured

humidity.

15000 Dealer Name

[Dealer Name]

None

Both

No

15000 Dealer Phone

[Dealer Phone]

None

Both

No

15010 Dealer Email

Address

[Dealer Email Address]

None

Both

No

15010 Dealer Website

[Dealer Website]

None

Both

No

15020 Dealer Message

[Dealer Message]

None

Both

No

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,