Wiring, Iaq equipment or a heat/cool stage to the, On.see “wiring iaq – Honeywell PRESTIGE THX9321 User Manual

Page 149: Thx9321 prestige, Iaq with eim

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

149

68-0311—02

Wiring IAQ Equipment or a Heat/Cool Stage to the Universal Terminals

To Equipment Interface Module

“U” terminals can be used for humidification, dehumidification or ventilation.

Fig. 339. Wiring a powered humidifier.

Fig. 340. Wiring a powered ventilator.

Fig. 341. Wiring a powered dehumidifier (whole house

dehumidifer).

Fig. 342. Wiring a non-powered humidifier.

Fig. 343. Wiring a non-powered ventilator.

Fig. 344. Wiring a low speed fan for dehumidification.

1Any combination of universal relays (U1, U2, U3) can be used. They are set in the thermostat installer setup.

2Wire the universal EIM relay to the low speed fan for dehumidification control at the equipment. The EIM relay can be set to be

normally open or normally closed in the thermostat installer setup.

POWERED

HUMIDIFIER

RH
RC
R
C

U3
U3
U2
U2
U1

U1

24

VAC

120

VAC

24

VAC

120

VAC

24

VAC

1

POWERED

VENTILATOR

RH
RC
R
C

24

VAC

U3
U3
U2
U2
U1

U1

24

VAC

120

VAC

24

VAC

120

VAC

1

POWERED

DEHUMIDIFIER

RH

RC

R

C

U3

U3

U2

U2

U1

U1

24

VAC

120

VAC

24

VAC

120

VAC

24

VAC

1

FIELD INSTALLED

JUMPER BETWEEN

R AND U1

RH
RC
R
C

24 VAC

U3
U3
U2
U2
U1

U1

NON-POWERED

HUMIDFIER

24

VAC

120

VAC

1

FIELD INSTALLED

JUMPER BETWEEN

R AND U1

RH
RC
R
C

24 VAC

U3
U3
U2
U2
U1

U1

NON-POWERED

VENTILATOR

24

VAC

120

VAC

1

FIELD INSTALLED

JUMPER BETWEEN

R AND U1

RH
RC
R
C

24 VAC

U3
U3
U2
U2
U1

U1

OR

DEHUMIDIFICATION

WITH LOW SPEED FAN

24

VAC

120

VAC

1

2

Normally open, dry contacts

Normally closed, dry contacts

Advertising
This manual is related to the following products: