Installation options, Guidelines for installing redlink devices – Honeywell PRESTIGE THX9321 User Manual

Page 9

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

9

68-0311—02

INSTALLATION OPTIONS

The THX9321 Prestige

®

2.0 thermostat is wired directly to the equipment. The THX9421 Prestige

®

IAQ thermostat is used with the

Equipment Interface Module or with a TrueZONE Wireless Adapter.

If using the Equipment Interface Module, see “Installing Equipment Interface Module (if used)” beginning on page 10.

If using a TrueZONE wireless adapter, follow the installation instructions that came with the TrueZONE, and go to “Selecting

Thermostat Location” beginning on page 12.

Guidelines for Installing RedLINK

Devices

— When installing more than one Thermostat and Equip-

ment Interface Module, mount the Equipment Interface

Modules at least 2 feet apart for best RedLINK perfor-

mance. No minimum distance is required between the

Thermostats if the Thermostat is linked to an Equip-

ment Interface Module.

— When the Thermostat is wired directly to the equipment

(No Equipment Interface Module and No TrueZONE

Wireless Adapter), mount the Thermostats at least 2

feet apart for best RedLINK performance.

— To determine if a RedLINK device will communicate

properly in the installed location, during the connection

process, press and quickly release the connect button

on the RedLINK device at the desired mounting loca-

tion. If the RedLINK device connects, then it will work

reliably during normal operation. If the RedLINK device

does NOT connect, try a new location. During the con-

nection process, the signal is sent at low power and

during normal operation the signal is sent at high

power.

— To connect a RedLINK device, make sure to press and

quickly release the connect button on the RedLINK

device. Press and holding the connect button down too

long will not allow the device to connect.

— If you link the Thermostat to the TrueZONE Wireless

Adapter, you will NOT be able to do the following: con-

trol humidification, dehumidification or ventilation, setup

a program schedule remotely from a computer, smart

phone or tablet, work with the Wireless Indoor Sensor,

Entry / Exit Remote or the Vent and Filter Boost

Remote. To use these features, wire the Thermostat

directly to the zone panel or use an Equipment Inter-

face Module.

— If you are using a RedLINK device from a previous

installation, you must reset the device first before you

re-connect it to the new Thermostat/Equipment Inter-

face Module. See page 134 for more information.

TM

TM

OR

THX9421 THERMOSTAT –

2 WIRES FOR POWER

RedLINK TO EQUIPMENT INTERFACE MODULE

RedLINK TO TrueZONE WIRELESS ADAPTER

THX9421 THERMOSTAT –

2 WIRES FOR POWER

THX9321 THERMOSTAT

WIRED DIRECTLY TO EQUIPMENT

OR

MCR34631

WIRED DIRECTLY TO E

Advertising