Thx9321 prestige, Iaq with eim – Honeywell PRESTIGE THX9321 User Manual

Page 145

Advertising
background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

145

68-0311—02

Fig. 333. Wood stove-fired hot water fan coil with forced air

furnace backup heat.

Fig. 334. Hot water radiant heat with backup heat (single

zone application).

W

W2

W3

W

Y

G

R

C

CONFIGURE THE THERMOSTAT TO ENERGIZE THE FAN

WITH A CALL FOR HEAT.

THE THERMOSTAT WILL ENERGIZE ONLY THE FAN WITH

A CALL FOR STAGE 1 HEAT. IF THE WOOD STOVE IS HOT,

HEAT COMES FROM THE FAN COIL. IF THE WOOD STOVE

IS COLD, ONLY THE FAN RUNS. THE THERMOSTAT WILL

UPSTAGE TO THE FURNACE AS NEEDED TO MAINTAIN

THE TEMPERATURE.

L

TO THERMOSTAT

THERMOSTAT/EIM

CONV

FURNACE

M31482

1

2

1

2

W

W2

W3

W

Y

G

R

C

THE BOILER IS CONTROLLING THE CIRCULATOR PUMP

IN THIS DIAGRAM.

L

TO THERMOSTAT

THERMOSTAT/EIM

CONV

FURNACE

M31483

1

1

BOILER

T

T

RELAY

3

1

Advertising