Installer options

Installer Options require a password and should only be

changed by a qualified technician.

To prevent unintended changes or damage to your equipment,

do not change these options yourself.

Fig. 144.

Using the temperature display

In some circumstances, the temperature displayed on the

Home screen may not match the temperature near the

thermostat.

If your system is set up to use remote indoor sensors, it may be

reading a sensor in another location.

Fig. 145.

Using the humidity display

In some circumstances, the humidity displayed on the Home

screen may not match humidity near the thermostat.

Some systems are set up to use two sensors, one to control

humidification, the other for dehumidification. These sensors

are often installed in different locations.

Depending on how your thermostat was installed, the

thermostat Home screen will display humidity readings from

only one sensor.

Fig. 146.

UNIVERSAL OUTPUTS

(U1, U2, U3)

U1, U2, U3 are universal outputs that can be setup to control

IAQ equipment and a stage of heating or cooling in the Installer

Setup. Setup options are listed below. See “THX9321

Thermostat Wiring Diagrams Using Universal Relays to

Control Heating or Cooling” beginning on page 142 for more

information.

Universal Output Options

THX9421 with Equipment Interface Module (U1, U2, U3):

• Humidification (ISU 8030)

• Dehumidification (ISU 9040)

• Ventilation (ISU 10020)

• Cool Stage 3 (ISU 2080)

• Cool Stage 4 (ISU 2090)

• Geothermal Radiant Heat (ISU 2030, 2040)

THX9321 Thermostat Only (U1, U2)

• Humidification (ISU 8030)

• Dehumidification (ISU 9040)

• Ventilation (ISU 10020)

• Cool Stage 3 (ISU 2080)

• Cool Stage 4 (ISU 2090)

• Conventional Heat Stage 3 (ISU 2100, 2140)

• Backup Heat Stage 2 for Heat Pumps (ISU 2170)

• Geothermal Radiant Heat (ISU 2030, 2040)